Dedicated motor (SF-V5RU(H)) outline dimension drawings
SF-V5RUF(H)
1KB
Connector (for encoder)
MS3102A20-29P
Terminal box for cooling fan
LL
KB
Exhaust
terminal box
Suction
Section
1
2
Direction of
cooling fan wind
Earth (ground) terminal (M5)
Mark for earthing (grounding)
SF-V5RUF(H)
11KB 15KB
,
Dimensions table
SF-V5RUFB
SF-V5RUFB1
SF-V5RUFB3
SF-V5RUFB4
Flange
Frame
Output
Output
Output
Output
Number
No.
(kW)
(kW)
(kW)
(kW)
1.5
FF165
90L
2.2
1.5
FF215
100L
3.7
2.2
1.5
FF215
112M
5.5
3.7
2.2
FF265
132S
7.5
5.5
3.7
1.5
FF265 132M
11
7.5
5.5
2.2
FF300 160M
15
11
7.5
3.7
FF300
160L
Note) 1. Install the motor on the floor and use it with the shaft horizontal.
For use under the shaft, the protection structure of the cooling fan is IP20.
2. Leave an enough clearance between the fan suction port and wall to ensure adequate cooling.
Also, check that the ventilation direction of a fan is from the opposite load side to the load side.
3 The size difference of top and bottom of the shaft center height is
4 The 400V class motor has -H at the end of its type name.
5. Since a brake power device is a stand-alone, install it inside the enclosure.
(This device should be arranged at the customer side.)
LR
LG
LE
KL
Q
Main
QK
LN LZ
AA
1
B
A
B
A
2
W
S
Main terminal box
For brake (B1, B2)
Section BB
For motor (U, V, W)
For thermal protector (G1, G2)
B1
B2
U
V
W
G1 G2
Connector (for encoder)
MS3102A20-29P
Terminal box for cooling fan
LL
Exhaust
Suction
1, 2
Direction of
cooling fan wind
Earth (ground) terminal (M8)
Mark for earthing (grounding)
Main terminal box
For motor (U, V, W)
Earthing
U
V
W
(grounding)
terminal
B1
B2
G1
G2
For brake (B1, B2)
For thermal protector (G1, G2)
Mass
(kg)
D
KB
KD
KL
KP
LA
31.5
183.6 198.5
27
220
155
165
50
207
213
27
231
165
215
58
228
239
27
242
178
215
83
266
256
27
256
197
265
88
266
294
27
256
197
265
151
318
318
56
330
231
300
167
318
362
56
330
231
300
0
-0.5
(1500r/min series)
SF-V5RUF(H)
2KB
,
3KB
Connector (for encoder)
Terminal box for cooling fan
MS3102A20-29P
LL
Exhaust
Suction
1
2
Direction of
cooling fan wind
Earth (ground) terminal (M5)
Mark for earthing (grounding)
Terminal box for cooling fan
For cooling fan (A, B)
A
B
C
Earthing
Earthing
(grounding)
(grounding)
terminal
terminal
KB
LR
KL
LG
LE
Main
Q
terminal box
1
QK
Section
AA
A
B
B
A
Terminal box for cooling fan
For cooling fan (A, B, C)
A
B
C
indicates an inserting position of a bolt with hex head holes
Earthing
(grounding)
for manual opening.
terminal
Make sure to earth the earth terminal of the flange section
as well as the earth terminal in the terminal box.
Motor
LB
LC
LE
LG
LL
LN
LZ
130j6
200
3.5
12
442
4
12
180j6
250
4
16
481.5
4
14.5
180j6
250
4
16
525
4
14.5
230j6
300
4
20
597
4
14.5
230j6
300
4
20
635
4
14.5
250j6
350
5
20
735.5
4
18.5
250j6
350
5
20
779.5
4
18.5
Outline dimension drawings
(flange type with brake)
,
5KB
,
7KB
LR
KB
Q
KL
LG
LE
1
Main
QK
terminal box
A
Section
AA
B
B
A
W
S
Section BB
LN
LZ
2
W
S
Section BB
Shaft End
Terminal Screw Size
LR
Q
QK
S
T
U
W
U,V,W A,B,(C) B1,B2 G1,G2
50
50
40
24j6
7
4
8
M6
60
60
45
28j6
7
4
8
M6
60
60
45
28j6
7
4
8
M6
80
80
63
38k6
8
5
10
M6
80
80
63
38k6
8
5
10
M6
110
110
90
42k6
8
5
12
M8
110
110
90
42k6
8
5
12
M8
LN
LZ
2
(Unit: mm)
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
6
173