Parameter
Name
Eighth position feed
479
amount lower 4 digits
Eighth position feed
480
amount upper 4 digits
Ninth position feed
481
amount lower 4 digits
Ninth position feed
482
amount upper 4 digits
Tenth position feed
483
amount lower 4 digits
Tenth position feed
484
amount upper 4 digits
Eleventh position feed
485
amount lower 4 digits
Eleventh position feed
486
amount upper 4 digits
Twelfth position feed
487
amount lower 4 digits
Twelfth position feed
488
amount upper 4 digits
Thirteenth position feed
489
amount lower 4 digits
Thirteenth position feed
490
amount upper 4 digits
Fourteenth position feed
491
amount lower 4 digits
Fourteenth position feed
492
amount upper 4 digits
Fifteenth position feed
493
amount lower 4 digits
Fifteenth position feed
494
amount upper 4 digits
Remote output
495
selection
496
Remote output data 1
497
Remote output data 2
503
Maintenance timer
Maintenance timer
504
alarm output set time
505
Refer to Pr. 37.
—
516 to 519
Refer to Pr. 29.
—
USB communication
547
station number
USB communication
548
check time interval
Refer to Pr. 338 and Pr. 339.
551
549
Refer to Pr. 117.
—
550, 551
Refer to Pr. 338 and Pr. 339.
Incre
Initial
Range
ments
Value
1
0
0 to 9999
REX
1
0
0 to 9999
1
0
0 to 9999
REX, RL
1
0
0 to 9999
1
0
0 to 9999
REX, RM
1
0
0 to 9999
1
0
0 to 9999
REX, RM, RL
1
0
0 to 9999
1
0
0 to 9999
REX, RH
1
0
0 to 9999
1
0
0 to 9999
REX, RH, RL
1
0
0 to 9999
1
0
0 to 9999
REX, RH, RM
1
0
0 to 9999
1
0
0 to 9999
REX, RH, RM, RL
1
0
0 to 9999
0
Remote output data clear at powering off
1
0
Remote output data retention even at
1
powering off
1
0
0 to 4095
Output terminal can be switched on and
off.
1
0
0 to 4095
Display the cumulative energization time of
the inverter in 100h increments.
1
0
0 (1 to 9998)
Reading only
Writing the setting of "0" clears the
cumulative energization time.
Set the time taken until when the
0 to 9998
maintenance timer alarm output signal
1
9999
(Y95) is output.
9999
No function
1
0
0 to 31
Specify the inverter station number.
USB communication is enabled. However,
the inverter will come to an alarm stop (E.
0
USB) if operation is changed to PU
operation mode.
0.1s
9999
0.1 to
Set the interval of communication check
999.8s
time.
9999
No communication check
Parameter List
Param
eter
copy
Description
Speed 8 (Pr.232)
Speed 9 (Pr.233)
Speed 10 (Pr.234)
Speed 11 (Pr.235)
Speed 12 (Pr.236)
Speed 13 (Pr.237)
Speed 14 (Pr.238)
Speed 15 (Pr.239)
×
×
×
All
Param
param
eter
eter
clear
clear
: enabled
× : disabled
×
×
×
×
×
×
3
×
121