Mitsubishi Electric FR-A700 Series Instruction Manual page 121

Hide thumbs Also See for FR-A700 Series:
Table of Contents

Advertisement

Parameter List
Parameter
286
Droop gain
Droop filter time
287
constant
Droop function
288
activation selection
Pulse train I/O
291
selection
Input pulse division
384
scaling factor
Frequency for zero
385
input pulse
Frequency for
maximum input
386
pulse
292, 293
Refer to Pr. 61.
294
Refer to Pr. 261.
299
Refer to Pr. 57.
331 to 337
Refer to Pr. 117.
116
Incre
Initial
Name
ments
Value
0.1%
0%
0.01s
0.3s
1
0
1
0
1
0
0.01Hz
0
0.01Hz
60Hz
Range
Description
0
Droop control is invalid
Set the drooping amount at the rated
0.1 to
torque as a percentage with respect to the
100%
rated frequency.
Set the time constant of the primary delay
0 to 1s
filter applied to the torque current.
Real sensor less
vector /vector
control
Droop control is not
exercised during
acceleration/
deceleration.
0, 10
(When Pr.288 = 10,
droop compensation
amount is determined
using the motor
speed as reference.)
Droop control is
always exercised
during operation.
(with 0 limit)
1, 11
(When Pr.288 = 11,
droop compensation
amount is determined
using the motor
speed as reference.)
Droop control is
always exercised
2
during operation.
(without 0 limit)
Input
0
JOG terminal
1
Pulse train input
10
JOG terminal
11
Pulse train input
20
JOG terminal
21
Pulse train input
100
Indicates division scaling factor to the input
pulse and the frequency resolution to the
0 to 250
input pulse changes according to the
value.
Set the frequency when the input pulse is 0
0 to 400Hz
(bias).
Set the frequency when the input pulse is
0 to 400Hz
maximum (gain).
Param
Param
eter
eter
copy
clear
: enabled
× : disabled
Advanced
magnetic flux
vector control
Droop control is not
exercised during
acceleration/
deceleration.
Droop
compensation
amount is
determined using
the rated motor
frequency as
reference.
Output
FM output
FM output
Pulse train open
collector output
(50% duty)
Pulse train open
collector output
×
(ON width is always
same)
Pulse train open
collector output
(ON width is always
same
(independently of
Pr. 54))
All
param
eter
clear

Advertisement