2.7 [1] Configuration
Parallel Telephone Ringing (for S-Hybrid port)
Specifies whether the sub telephone (SLT) rings at the same time as the main telephone (DPT) for
an incoming call.
Default
Yes
Value Range
Yes, No
Maintenance Console Location
2.7.5 [1-1] Slot—Extension Port
Programming Manual References
None
Feature Manual References
1.13.2 Paralleled Telephone
DPT Type—Type (for DPT or S-Hybrid port)
Selects the port type.
To change the port type of an extension port, follow the steps below:
1.
Set the status of the extension port to "OUS".
2.
Change the port type of the extension port, then click Apply.
3.
Set the status of the extension port to "INS".
When changing the port type of an extension port for which Wireless XDP has been set on the
2.10.1 [4-1-1] Wired Extension—Extension Settings screen, the Wireless XDP setting must
be deleted first.
Default
Normal
Value Range
Normal: For connecting a DPT
DSS: For connecting a DSS Console (A maximum of 4 [with the KX-TDA50], 8 [with the KX-TDA100/
KX-TDA200] or 64 [with the KX-TDA600] DSS Consoles can be connected to the PBX.)
VM (DPT): For connecting a Panasonic VPS through DPT Integration
PC Console: For connecting a PC Console (A maximum of 2 [with the KX-TDA50] or 8 [with the KX-
TDA100/KX-TDA200/KX-TDA600] PC Consoles can be connected to the PBX.)
Maintenance Console Location
2.7.5 [1-1] Slot—Extension Port
Programming Manual References
2.7.6 [1-1] Slot—Extension Port—Port Command