Figure 30
1. Fuel Filter
Figure 31
1. Radiator screen cover
Figure 32
1. Radiator cap
2. Clean out door
2. Reserve tank cap
Figure 33
1. Governor belt
2. Alternator belt
Figure 34
1. Fan belt
CHECKING THE OIL LEVEL IN
THE GOVERNOR
Check the oil level in the governor after every 600
hours of operation.
1. Position the vehicle on level surface, stop the
engine and engage the parking brake.
2. Raise box (if so equipped) and place safety sup-
port on extended lift cylinder to hold up box.
3. Clean the area around the check plug on the gov-
ernor.
4. Remove the check plug from the governor. The
oil level must be up to the bottom of hole. If the
oil level is low, remove the oil fill plug and add
the same oil that is being used in the engine.