U2
00
Content
EEPROM read/write error (ICU).
Details
Write error to EEPROM.
Cause
EEPROM trouble.
Installation of EEPROM which is not
initialized.
ICU PWB EEPROM access circuit trouble.
Check &
Check that the EEPROM is properly set.
Remedy
To save the counter data/adjustment values,
make notes of the counter/adjustment values
with the simulation.
Cancel the U2 trouble with SIM16.
Replace the ICU PWB.
22
Content
SRAM memory check sum error (ICU).
Details
SRAM memory check sum error in the MFPC
section.
Cause
SRAM trouble.
Hung up of the control circuit caused by
noises.
ICU PWB SRAM access circuit trouble.
Check &
Initialize the communication management
Remedy
table registered in the SRAM and the FAX
soft switches.
Registered contents are deleted. Register
the deleted contents again.
Cancel the U2 trouble with SIM16.
Replace the ICU PWB.
23
Content
SRAM memory individual data check sum
error (ICU).
Details
MFPC section SRAM memory individual
data check sum error (Communication
management table, sender registration data,
etc).
Cause
SRAM trouble.
Hung up of the control circuit caused by
noises.
ICU PWB SRAM access circuit trouble.
Check &
Turn OFF/ON the power to automatically
Remedy
initialize the data related to the contents
where a check sum error occurred.
Registered contents are deleted. Register
the deleted contents again.
Cancel the U2 trouble with SIM16.
Replace the ICU PWB.
50
Content
HD section individual data check sum error
(ICU).
Details
MFPC section HD individual data check sum
error (One-touch, group, program, etc).
Cause
Write/read error from/to HD.
Hung up of the control circuit caused by
noises.
ICU PWB HD access circuit trouble.
Check &
Turn OFF/ON the power to automatically
Remedy
initialize the data related to the contents
where a check sum error occurred.
Registered contents are deleted. Register
the deleted contents again.
Cancel the U2 trouble with SIM16.
Replace the HD PWB.
Replace the ICU PWB.