Specifications of system equipment
 System specifications
Model name
Number of units
Server blade
that can be
I/O board module (PCI Express Board)
installed
Switch module
Management module
Power supply module
Fan module
AC power input module
Outside dimensions (W x D x H: mm)/number of units
according to the Electronic Industries Alliance (EIA),
standard
Mass (Maximum)
Power source
Input voltage (Frequency)
Rated power *2
Environmental
Temperature in Celsius
requirement
Humidity in percent
(There must be no condensation.)
EMC standard
Noise
Rated wind
*1
The number of server blade may be limited in the redundancy configuration with 1+1 power
supplies.
*2
This is the rated value of a server chassis. The actual power consumption changes
depending on configuration of blades and modules.
*3
This equipment controls RPM of a fan based on inlet air temperatures and internal
temperatures. This value may be exceeded when the inlet air is 25°C or higher; CPU is
under heavy load; or one of the fans fails.
*4
This equipment controls RPM of a fan based on inlet air temperatures and internal
temperatures. This value may be exceeded when the inlet air is 35°C or higher, or one of
the fans fails.
Compute Blade 2000
Up to 8 units *1
Up to 16 units
Up to 6 units
Up to 2 units
One unit under the standard configuration
Max: up to 4 units
8 units in redundant configuration
2 units
447 x 820 x 441 mm/10U
180 kg
AC200 V ~ 240 V single phase (50/60 Hz)
8 kW
5°C to 35°C
20% to 80%
FCC, ICES, EN55022, EN55024, EN61000,
KC KN24, KC KN22, C-Tick, GOST, BSMI,
CCC
64 dB *3
3
17.2 m
/min: 607 CFM *4
2