PARAMETER LIST
Name
Pr.
Regeneration avoidance
883
operation level
Regeneration avoidance
885
compensation frequency limit
value
Regeneration avoidance
886
voltage gain
888
Free parameter 1
889
Free parameter 2
Cumulative power monitor
891
digit shifted times
C1
AM terminal calibration
(901)
∗4
C2
Terminal 2 frequency setting
(902)
bias frequency
∗4
C3
Terminal 2 frequency setting
(902)
bias
∗4
125
Terminal 2 frequency setting
(903)
gain frequency
∗4
C4
Terminal 2 frequency setting
(903)
gain
∗4
C5
Terminal 4 frequency setting
(904)
bias frequency
∗4
C6
Terminal 4 frequency setting
(904)
bias
∗4
126
Terminal 4 frequency setting
(905)
gain frequency
∗4
C7
Terminal 4 frequency setting
(905)
gain
∗4
C22
(922)
∗4
C23
(922)
∗4
Parameter for manufacturer setting. Do not set.
C24
(923)
∗4
C25
(923)
∗4
990
PU buzzer control
991
PU contrast adjustment
Pr.CL Parameter clear
ALLC All parameter clear
Er.CL Faults history clear
Pr.CH Initial value change list
18
Initial
Setting Range
Value
400VDC/
300 to 800V
780VDC
∗5
0 to 10Hz, 9999
6Hz
0 to 200%
100%
0 to 9999
9999
0 to 9999
9999
0 to 4, 9999
9999
-
-
0 to 400Hz
0Hz
0 to 300%
0%
0 to 400Hz
60Hz
0 to 300%
100%
0 to 400Hz
0Hz
0 to 300%
20%
0 to 400Hz
60Hz
0 to 300%
100%
0, 1
1
0 to 63
58
0, 1
0
0, 1
0
0, 1
0
∗1
Differ according to capacities.
6%: FR-D720-042 or lower, FR-D740-022 or lower, FR-D720S-042 or
lower, FR-D710W-042 or lower
4%: FR-D720-070 to 165, FR-D740-036 to 080, FR-D720S-070 and 100
3%: FR-D720-238 and 318, FR-D740-120 and 160
∗2
Differ according to capacities.
5s: FR-D720-165 or lower, FR-D740-080 or lower, FR-D720S-008 to
100, FR-D710W-042 or lower
10s: FR-D720-238 and 318, FR-D740-120 and 160
∗3
Differ according to capacities.
6%: FR-D720-008 and 014, FR-D720S-008 and 014, FR-D710W-008 and
014
4%: FR-D720-025 to 318, FR-D740-012 to 160, FR-D720S-025 to 100,
FR-D710W-025 and 042
∗4
The parameter number in parentheses is the one for use with the
operation panel (FR-PA02) for the FR-E500 series or parameter unit (FR-
PU04/FR-PU07).
∗5
The initial value differs according to the voltage class. (100V, 200V class/
400V class)
∗6
Available only for the three-phase power input model.
∗7
The setting value "60" is only available for Pr. 178.
∗8
The setting value "61" is only available for Pr. 179.
∗9
The setting value "93" and "193" are only available for Pr. 190 and Pr. 197.
∗10 The setting value "9999" is only available for Pr. 190 and Pr. 192.