Mitsubishi Electric FR-D720-008 Installation Manuallines page 20

Hide thumbs Also See for FR-D720-008:
Table of Contents

Advertisement

Name
Pr.
RUN terminal function
190
selection
A,B,C terminal function
192
selection
197
SO terminal function selection
232
Multi-speed setting (speed 8)
233
Multi-speed setting (speed 9)
Multi-speed setting (speed
234
10)
235
Multi-speed setting (speed 11)
Multi-speed setting (speed
236
12)
Multi-speed setting (speed
237
13)
Multi-speed setting (speed
238
14)
Multi-speed setting (speed
239
15)
240
Soft-PWM operation selection 0, 1
Analog input display unit
241
switchover
Cooling fan operation
244
selection
245
Rated slip
Slip compensation time
246
constant
Constant-power range slip
247
compensation selection
Earth (ground) fault detection
249
at start
250
Stop selection
Output phase loss protection
251
selection
255
Life alarm status display
Inrush current limit circuit life
256
display
Control circuit capacitor life
257
display
Main circuit capacitor life
258
display
Main circuit capacitor life
259
measuring
PWM frequency automatic
260
switchover
261
Power failure stop selection
267
Terminal 4 input selection
Initial
Setting Range
Value
0, 1, 3, 4, 7, 8,
11 to 16, 25, 26,
0
46, 47, 64, 70,
80, 81, 90, 91,
93
, 95, 96, 98,
∗9
99, 100, 101,
103, 104, 107,
99
108, 111 to 116,
125, 126, 146,
147, 164, 170,
180, 181, 190,
191, 193
,
∗9
80
195, 196, 198,
199, 9999
∗10
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
1
0, 1
0
0, 1
1
0 to 50%, 9999
9999
0.01 to 10s
0.5s
0, 9999
9999
0, 1
0
0 to 100s, 1000
to 1100s, 8888,
9999
9999
0, 1
1
(0 to 15)
0
(0 to 100%)
100%
(0 to 100%)
100%
(0 to 100%)
100%
0, 1 (2, 3, 8, 9)
0
0, 1
0
0, 1, 2
0
0, 1, 2
0
Name
Pr.
Monitor decimal digits
268
selection
269
Parameter for manufacturer setting. Do not set.
Magnitude of frequency
295
change setting
296
Password lock level
297
Password lock/unlock
298
Frequency search gain
Rotation direction detection
299
selection at restarting
Communication operation
338
command source
Communication frequency
339
command source
Communication startup mode
340
selection
Communication EEPROM
342
write selection
343
Communication error count
450
Second applied motor
495
Remote output selection
496
Remote output data 1
Stop mode selection at
502
communication error
503
Maintenance timer
Maintenance timer alarm
504
output set time
549
Protocol selection
PU mode operation command
551
source selection
555
Current average time
556
Data output mask time
Current average value
557
monitor signal output
reference current
PTC thermistor protection
561
level
Energization time carrying-
563
over times
Operating time carrying-over
564
times
571
Holding time at a start
Output interruption detection
575
time
Output interruption detection
576
level
Output interruption cancel
577
level
611
Acceleration time at a restart
653
Speed smoothing control
Regeneration avoidance
665
frequency gain
Input phase loss protection
872
∗6
selection
Regeneration avoidance
882
operation selection
PARAMETER LIST
Initial
Setting Range
Value
0, 1, 9999
9999
0, 0.01, 0.10,
1.00, 10.00
1 to 6,
101 to 106,
9999
9999
1000 to 9998
9999
(0 to 5, 9999)
0 to 32767,
9999
9999
0, 1, 9999
0, 1
0, 1, 2
0, 1, 10
0, 1
0, 1, 9999
9999
0, 1, 10, 11
0 to 4095
0, 1, 2
0 (1 to 9998)
0 to 9998, 9999
9999
0, 1
2, 4, 9999
9999
0.1 to 1s
0 to 20s
Rated
0 to 500A
inverter
current
0.5 to 30kΩ,
9999
9999
(0 to 65535)
(0 to 65535)
0 to 10s, 9999
9999
0 to 3600s, 9999
0 to 400Hz
0Hz
900 to 1100%
1000%
0 to 3600s, 9999
9999
0 to 200%
0 to 200%
100
0, 1
0, 1, 2
0
0
0
0
0
0
0
0
0
0
0
0
1s
0s
0
0
1s
0
0
0
17