Operator Cab Fuses (Groundsmaster 4010- -D)
The cab fuse blocks are located in the cab headliner
(Fig. 19).
Identification and Function (Figs. 19 and 20)
Fuse F1--2 (15 Amp) protects the cab fan circuit.
Fuse F1--3 (30 Amp) protects the air conditioner circuit.
Fuse F2--1 (15 Amp) protects the windshield wiper/
washer circuit.
Fuse F2--2 (15 Amp) protects the cab dome light circuit.
Fuses F1--1, F1--4, F2--3 and F2--4 are available for op-
tional equipment.
Testing
Turn ignition switch to the ON position (do not start en-
gine). With the fuse installed in the fuse block, use a
multimeter to verify that 12 VDC exists at both of the ter-
minal test points on the fuse. If 12 VDC exists at one of
the fuse test points but not at the other, the fuse is faulty.
If necessary, make sure that ignition switch is OFF and
key is removed from switch. Remove fuse from fuse
block and check that fuse has continuity across the fuse
terminals.
Electrical System
1
1. Cab headliner switches
1
2
3
4
Page 5 - - 22
2
Figure 19
2. Cab fuse blocks
F1
F2
15 A
15 A
15 A
30A
Figure 20
Groundsmaster 4000--D/4010--D