Lift/Lower Manifold Service
5 ft- -lb
(6.7 N- -m)
4
9
10
25 ft- -lb
(34 N- -m)
20 ft- -lb
(27 N- -m)
11
1. Lift/lower manifold body
2. Solenoid valve (S4, S6 & S9)
3. Solenoid coil (5 used)
4. Nut (8 used)
NOTE: The ports on the lift/lower manifold are marked
for easy identification of components. Example: S1 is
solenoid valve S1 and P is the gear pump connection
port (see Hydraulic Schematic in Chapter 10 -- Foldout
Drawings to identify the function of the hydraulic lines
and cartridge valves at each port location).
Hydraulic System
20 ft- -lb
(27 N- -m)
8
7
3
6
5. Relief valve (RV2)
6. Relief valve (RV1)
7. Solenoid valve (S1)
8. Nut
Page 4 - - 142
25 ft- -lb
(34 N- -m)
5
3
10
Figure 112
NOTE: The lift/lower manifold assembly includes sev-
eral zero leak plugs. These plugs have a tapered sealing
surface on the plug head that is designed to resist vibra-
tion induced plug loosening. The zero leak plugs also
have an O--ring as a secondary seal. If zero leak plug re-
moval is necessary, lightly rap the plug head using a
punch and hammer before using an allen wrench to re-
move the plug: the impact will allow plug removal with
less chance of damage to the socket head of the plug.
4
5 ft- -lb
(6.7 N- -m)
3
2
12
20 ft- -lb
(27 N- -m)
20 ft- -lb
(27 N- -m)
1
2
20 ft- -lb
(27 N- -m)
11
9. Solenoid coil (4 used)
10. Solenoid valve (S2, S3, S7 & S8)
11. #4 zero leak plug with O- -ring
12. Solenoid valve (S5)
Groundsmaster 4000--D/4010--D