Function
Prohibit local remote control
Filter sign reset
Error reset
Operation
*1
Error history reset
External input
Operation status of each group
in the system
Filter sign
Monitor
Local operation prohibition
*1
Error
External output
Date and time
License
Unit Info.
Network
Operation
*1
Advanced settings
Groups
Blocks
Interlock
Monitor
Error history monitor
*1
External temperature interlock
Operation
Night setback control
*1
Interlock control
Maintenance User
Operation
*1
Building Manager
Connection/Interlock
Information
Error history
Schedule data
Data
Current time
back-up
Saving the data on a USB drive
Reading data from USB
memory
Device
Time synchronization
maintenance
*1: The item and range that can be operated or monitored depend on the function of the indoor unit.
*2: The maximum number of the controllable units varies, depending on the indoor unit.
*3: "Air To Water" on the GB-50ADA's web screen indicates Booster unit group and Water HEX unit group.
Operation of certain functions from the local remote controllers can be prohibited
collectively or for each group or blocks of indoor units.
(Applicable functions: ON/OFF, operation mode, temperature setting, filter sign)
Filter sign can be reset for each group or block of indoor units.
Resets the display of error.
Resets the error history (unit error, communication error).
Connects to an external input/output device that stops the units in an emergency,
run or stop the units, permit or prohibit the operation of units collectively. Requires
an external input/output adapter (sold separately) and external power supply
(12VDC or 24VDC).
Operation status (ON/OFF), operation mode, fan speed, temperature setting, air
flow direction, operation status (ON/OFF) of interlocked units, timer enable/disable
status of each group is displayed.
Indicates that the filters on the units in a given group is due for cleaning.
Displays the functions that the controller forbids or the functions that are forbidden
by other controllers.
The address of the unit in error, error code, and the address of the unit that detected
the error will appear.
Outputs signals (run/stop, error) to an external device. Requires an external input/
output adapter (sold separately) and external power supply (12VDC or 24VDC).
This function is used to set the current date/time and daylight savings time.
This function is used to register license.
This function is used to set unit name, ID number, date format, time format,
temperature unit.
This function is used to set the IP address, subnet mask address, and gateway
settings for the LAN and also to set the address for the M-NET, K-transmission
converter address, local control prohibit settings, and external input settings.
Allows the Master/Sub clock setting to be made.
This function is used to register indoor units, LOSSNAY units, remote controllers,
and sub system controllers to a group.
This function is used to register a group to a block.
This function is used to interlock the operation of indoor units and ventilation units.
Up to 128 errors can be stored in memory. (64 unit errors, 64 communication errors)
Control level of outside temperature interlock function can be set for each group.
Control time and upper/lower limit temperature can be set for setback function.
Interlock control can be performed between the connected devices by making
interlock settings (up to 150 settings).
Allows the maintenance user name and password to be set.
Allows the building manager name, password, function enable/disable settings to be
made.
Group setting information and interlock setting information are retained, even if
power is turned off.
Retained, even if power is turned off.
Schedule information of each group is retained, even if power is turned off.
Current time is retained by the build-in capacitor for a week, even if power is turned
off.
The initial setting data, operational data (charge parameter, power consumption)
can be stored to a USB drive.
Initial setting data can be read from USB memory.
Clocks on the controllers and units that are under the control of the main controller
are synchronized once a day (applicable only to the ones that support this function).
- 22 -