6-2. Items not included

The following items are required to install the AE-200/AE-50.
Items not included
Electrical box
(required only for installation
method 2)
Metal control box
(required only for installation
methods 3 and 4)
Locknuts and bushing
Sleeved ring terminal
AC power cable/Protective
ground wire
Transmission cable
LAN cable
Switching HUB
Fuse
Overcurrent
breaker (fuse or
circuit breaker)
Circuit breaker
Earth leakage breaker
*1 PE: Polyethylene, PVC: Polyvinyl chloride
6-3. Items sold separately
Items sold separately
Electrical box
L-fittings
Mounting kit
DIN rail attachments
External input/output adapter
WT07137X01
Model: PAC-YG84UTB-J
Must be suitable for the AE-200/AE-50 installation.
Minimum metal thickness when using installation method 4: 200 mm (7-7/8 in)
Must be suitable for the conduit tube to be used.
M3.5 ring terminal (for AC power cables (L/L1, N/L2) and M-NET transmission cables (A, B,
S))
M4 ring terminal (for protective ground wire)
Type: Sheathed vinyl wire (should not be lighter than ordinary PVC sheathed flexible cord
IEC 60227.)
(designation 60227 IEC 52)
Size: 0.75 to 2.00 mm² (ø1.0 to ø1.6 mm), AWG 18 to 14
Protective ground wire color: green/yellow
* Use a wire with an appropriate diameter so that the wire can be fixed with the cable tie below the
terminal block. A diameter of 10 mm (25/64 in) is recommended.
Type: Sheathed vinyl cable
● CPEVS ø1.2 to ø1.6 mm
● CVVS Min. 1.25 to 2 mm²
* CPEVS: PE
insulated PVC
*1
* CVVS: PVC
*1
insulated PVC
Category 5 or above straight cable (Max. 100 m (328 ft))
A communication speed of 100 Mbps or faster is recommended.
Rated current: 3 A
* When using a fuse, use it in combination with a switch (rated current: 3 A).
Type: Bipolar (2P2E)
Contact distance: Min. 3 mm (1/8 in)
Rated current: 3 A
Type: Bipolar (2P2E)
Contact distance: Min. 3 mm (1/8 in)
Rated current: 3 A
Rated current sensitivity:30 mA
Operation time: Max. 0.1 sec
Model name
PAC-YG84UTB-J
PAC-YE86TK-J
PAC-YG10HA-E
22
Specifications
jacketed shielded communication cable
*1
*1
jacketed shielded control cable
Required only for installation method 2
Required only for installation method 4
Required when using the external input/output function
Remarks