66
DS_SYS_SoftwareVersionDiagnosticsGet
1204
Get the version of the diagnostics software on the digital board
-
Read the segment header in FLASH and determine Diagnostics software version
Less than 1 second
None
Number
Description
120400
Getting the Diagnostics software version succeeded
120401
Getting the Diagnostics software version failed
DS:> 1204
120400: Software Diagnostics Version = 0001
Test OK @
120503
Something went wrong while transferring the data.
120504
User cancelled the upload.
DS:> 1205 1
120500:
Test OK @
DS_SYS_EepromUpload
1205
Upload the contents of the NVRAM on the analog board or the digital board to the service PC,
by using the X-modem protocol
-
Decode the user input
-
Determine whether to upload the analog board or digital board NVRAM
-
Start uploading using the XMODEM protocol
-
Determine whether all was uploaded OK
Depends on the chosen NVRAM and the User.
Choose one of the following parameters for the nucleus:
1. Upload the contents of the NVRAM of the digital board
2. Upload the contents of the NVRAM of the analog board
Choose in the terminal on the control PC -> transfer -> receive file.
Select X-modem protocol. Then click receive in the dialogue and fill in the file name in which
you want to store the data.
Number
Description
120500
Download succeeded.
120501
User input is not valid.
120502
Something went wrong while copying the data from NVRAM to
SDRAM .