5.6.6. Tension Arm Offset Voltage Adjustment
Board
Specification
Test Point
Adjustment
Mode
M. EQ.
1. Set the VTR in EJECT mode and confirm the voltage at TP201 is in
the specification.
2. If it is not, adjust VR1 on the Mech. I/F Board so that the voltage is
in the specification.
5.6.7. Neutral Position Adjustment
Board
Specification
Test Point
Adjustment
Mode
M. EQ.
1. Remove 4 screws on the Front Loading Unit and Remove it, then
SERVO
2.5+/-0.05V
TP201(SERVO:F1)
VR1(Mech. IF)
EJECT
Digital Volt Meter
SERVO
2.5+/-0.1V
TP201(SERVO:F1)
Tension Regulator Board Base Position
STOP
Digital Volt Meter
VFK1208(Black, with a hole)
20