Vsm Line Filter Overtemperature Alarm Threshold / Vsmfilt_T A_Thresh; Vsm Line Filter Overtemperature Shutdown Threshold; Vsm Line Filter Overtemperature Hysteresis / Vsm Filt_T Hyst; Vsm 10 V Input Ct Gain / Vsm Ct_Gain - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

Dependency:
Refer to: p3665
Note:
For sensor type PTC (p3665 = 1), the following applies:
- below the nominal response temperature, r3666 = -50°C.
- above the nominal response temperature, r3666 = 199.9 °C.
p3667[0...n]

VSM line filter overtemperature alarm threshold / VSMfilt_T A_thresh

VECTOR_G
Can be changed: T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-100.00 [°C]
Description:
Sets the alarm threshold for the KTY temperature sensor of the Voltage Sensing Module (VSM) to monitor the line
filter temperature.
Prerequisite:
A KTY84 sensor is connected and p3665 is set to 2.
Dependency:
Refer to: p3665
p3668[0...n]
VSM line filter overtemperature shutdown threshold / VSM filt_T F_thres
VECTOR_G
Can be changed: T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-100.00 [°C]
Description:
Sets the shutdown threshold for the KTY temperature sensor of the VSM to monitor the line filter temperature.
Dependency:
Refer to: p3667
p3669[0...n]

VSM line filter overtemperature hysteresis / VSM filt_T hyst

VECTOR_G
Can be changed: T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
1.00 [K]
Description:
Sets the hysteresis for the alarm threshold of the VSM to monitor the line filter temperature.
Dependency:
Refer to: p3667
p3670[0...n]

VSM 10 V input CT gain / VSM CT_gain

VECTOR_G
Can be changed: T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: -
Min
0.000 [A]
Description:
Sets CT gain of the CT connected at the 10 V input of the Voltage Sensing Module (VSM).
The parameter specifies the current magnitude in [A] referred to the input voltage at the VSM in [V].
Example:
CT with 1 V per 200 A.
--> p3670 = 200
Dependency:
Refer to: r3671, r3672
Note:
The CT for phase 1 is connected at terminals X520.1 and X520.2 of the VSM.
The CT for phase 2 is connected at terminals X520.3 and X520.4 of the VSM.
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Calculated: -
Dyn. index: p0150
Units group: 21_1
Scaling: p2006
Max
301.00 [°C]
Calculated: -
Dyn. index: p0150
Units group: 21_1
Scaling: p2006
Max
301.00 [°C]
Calculated: -
Dyn. index: p0150
Units group: 21_2
Scaling: p2006
Max
50.00 [K]
Calculated: -
Dyn. index: p0150
Units group: -
Scaling: p2002
Max
1000.000 [A]
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 9886
Unit selection: p0505
Expert list: 1
Factory setting
150.00 [°C]
Access level: 3
Func. diagram: 9886
Unit selection: p0505
Expert list: 1
Factory setting
180.00 [°C]
Access level: 3
Func. diagram: 9886
Unit selection: p0505
Expert list: 1
Factory setting
3.00 [K]
Access level: 3
Func. diagram: 9880
Unit selection: -
Expert list: 1
Factory setting
1.000 [A]
573