Makita MAC1000 User Manual page 16

Oilless, single-stage, direct-drive, electric air compressor
Table of Contents

Advertisement

lotor will not run
Tank pressure exceeds preset
pressure switch limit
Motor overload protection has
tripped
Fuse Mown or circuit breaker
tripped
Check valve stuck open
Pressure bleeder valve on
pressure switch has not unloaded
head pressure
Wrong wire gauge in cord or
excessive extension cord length
Loose electrical connections
Possible defective capacitor
Paint spray on internal motor
parts
Possible defective motor
Motor will start automatically when tank pressure drops below
kick-in pressure of pressure switch.
Let motor cool
off,
and overload switch will automatically reset.
This may take several minutes.
Replace blown fuse or reset circuit breaker. Do not use fuse
or circuit breaker with higher rating than that specified for your
branch circuit.
0
Check for proper fuse; 'Fusetron" type T is acceptable.
Check for
low
voltage and proper extension cord size.
Disconnect other appliances from circuit. Operate compressor
on a dedicated circuit.
Remove and dean
o r
replace.
Bleed line by moving pressure switch lever to OFF position
before restarting. If bleeder valve does not open, replace
bleeder valve.
Check for proper gauge and extension cord length.
Contact authorized service center.
Have checked at service center.
Do
not operate the compressor
in
the
paint spray area.
Have checked at service center.
16
200-2 126

Advertisement

Table of Contents
loading

Table of Contents