Advertisement

User Manual
DP323C
ISSUE 2

Advertisement

Table of Contents
loading

Summary of Contents for Parweld DP323C

  • Page 1 User Manual DP323C ISSUE 2...
  • Page 2: Table Of Contents

    USER AND MAIINTENANCE MANUAL Parweld would like to thank you for choosing this machine; if used according to the instructions reported in this user and maintenance manual, it will accompany you in your work for many years without any problems. This manual is an integral part of the machine and must accompany it whenever moved or resold.
  • Page 4 www.parweld.com...
  • Page 5 www.parweld.com...
  • Page 6 www.parweld.com...
  • Page 7: Caution 2

    Caution: the device must only be used in the manner and for the purpose described in this manual. Never use inappropriately or for any other purpose. www.parweld.com...
  • Page 8 10. 20.Connector for supplying power to the liquid cooling system (Optional): Warning DISPLAYS: - When the screen comes on, the Parweld the connector contains dangerous logo will appear and the Firmware revisions will load. CONTROL BUTTONS: (2, 3, 4, 5,6 in fig.1)
  • Page 9: Loading The Welding Wire

    3. LOADING THE WELDING WIRE To load the welding wire, follow these instructions www.parweld.com...
  • Page 10 Remember that the spools with a ‘V’ cable are suitable for feeding iron and steel wire. The spools with a ‘U’ are suitable for aluminium wire. 4. MIG/MAG WELDING To choose this welding mode use switch 10, select MIG and press confirm. www.parweld.com...
  • Page 11: Mig/Mag Welding

    The welding current and the wire speed must be adjusted, taking into consideration the thickness of the workpiece. Larger pieces will require a higher wire speed. For best results, the wire speed must be adjusted during welding. soft-start: This adjusts the contact speed of the wire, www.parweld.com...
  • Page 12: Synergic Short Arc Mig Welding

    ‘welding tension’ setting. Welding quality can be further improved by adjusting the ‘electronic inductance’ and ‘deposit’ settings. Turn switch 10 to choose from the different MIG-MAG welding options; press the switch again to confirm the chosen option. www.parweld.com...
  • Page 13 (high values). welding current supply ends. Double short: This activates (ON) or deactivates (OFF) the two level option, i.e. the continuous switching between two different welding tension levels. L1 span: When the two level mode is active the www.parweld.com...
  • Page 14: Pulse Synergic Mig Welding

    Deposit: This modifies the deposit of the filler material (velocity of the wire) with respect to the pre-set synergic values. Double pulse: This activates (ON) or deactivates (OFF) the two level option, i.e. the continuous switching between two different welding tension levels. www.parweld.com...
  • Page 15: Mig Welding Conector

    MIG welding torch (Fig 4) This accessory has a long life-time if periodical controls of the gas nozzle and the wirefeeder tip are carried out (Fig 4A) (Fig 4B). These parts must be kept well-cleaned and intact. Replace the wire guide when the wire no longer threads correctly. www.parweld.com...
  • Page 16: Connector For Mig Welding With A Spool Or Push-Pull Torch

    The transfer methods of the filler material define different arc types: 1. Hold the torch at an angle of 45° from the workpiece. Keep the gas nozzle (Fig. 4A) at a distance of approximately 6 mm from the workpiece. www.parweld.com...
  • Page 17: Mma Welding

    Always make sure that the earth and the electrode clamp holder are kept far apart. Remote: This switches the remote control (which connects to socket 13 of fig.1) of the current intensity ON or OFF. www.parweld.com...
  • Page 18: Welding Table

    The electrode clamp holder and earth must be off the arc. connected to the ‘+’ and ‘-‘ terminals, according to the specifications of the electrodes used. www.parweld.com...
  • Page 19: Tig Welding

    2t: In 2 tempi mode, the machine welds for the entire time the torch trigger is pressed down. 4t: In 4 step mode, pressing the torch trigger once starts the welding process; press the button again to stop welding www.parweld.com...
  • Page 20: Connector For Tig Welding

    TIG torch on the workpiece (step 1 of fig.7); bring the tungsten electrode into contact with the workpiece, then press the torch trigger, whilst moving in a circular motion where the ceramic is positioned (see step 2 of fig.7). www.parweld.com...
  • Page 21: Power Connector

    3. Make sure that the gas tube is connected to the welder correctly. 4. Open the valve (1) of the cylinder (3). Press the torch trigger and check the gas is flowing correctly. To carry out this operation release the clutch of the motor. www.parweld.com...
  • Page 22: Ordinary Machine Maintenance

    2. You will then be asked to enter the password, which must be kept safe to make future modifications of the work point, should the need arise. www.parweld.com...
  • Page 23 (Reset pw) button. WARNING: The Reset Password option should only be used when there is no way of tracing the work stage and when the Lock/Unlock password has been lost. To use this function contact the Parweld technical support department directly. www.parweld.com...
  • Page 24 www.parweld.com...
  • Page 25: Troubleshooting

    Welding arc is too long Shorten the arc Scarce fusion fast torch movements Slow down torch movement Rusty material Clean Lateral incisions Welding speed is too high Reduce welding speed [display: no SD-card] The SD-card has been Insert SD-card removed www.parweld.com...
  • Page 26 www.parweld.com...
  • Page 27 26 Spare Parts www.parweld.com...
  • Page 28: Ec Declaration Of Conformity

    EC declaration of conformity Hereby we declare that the machines as stated below Type: DP323C Conform to the EC Directives: 73/23/EEC and 89/336/EEC European standard: EN/IEC 60974-1 This is to certify that the tested sample is in conformity with all provisions of the above detailed EU directives and product standards.
  • Page 29: Statement Of Warranty

    WEE compliance outside the UK please contact your supplier/Importer Parweld is registered with a compliance scheme Official registration number is WEE/FD0255QV When your equipment reaches the end of its service life you should return it to Parweld where it will be reconditioned or processed for recycling.
  • Page 30 Contact Your Local Distributor: Parweld Limited Bewdley Business Park Long Bank Bewdley Worcestershire Parweld Limited England Bewdley Business Park Long Bank DY12 2TZ Bewdley Worcestershire England DY12 2TZ tel. +44 1299 266800 fax. +44 1299 266900 tel. +44 1299 266800 fax.

This manual is also suitable for:

Dp403swDp503swDs403sw

Table of Contents