Page 2
Thank you and congratulations on choosing Parweld. This Owner’s Manual is designed to help you get the most out of your Parweld products. Please take time to read the Safety precautions. They will help you protect yourself against potential hazards in the workplace. With proper maintanance this equipment should provide years of reliable service.
Maintain unit according to manual. Wear a safety harness if working above floor level. Keep all panels and covers securely in place. Clamp work cable with good metal-to-metal contact to work piece or worktable as near the weld as practical. www.parweld.com...
15kg wire spools (300mm), an integral gas cylinder mounting undercarriage, an adjustable Argon flow regulator with cylinder pressure gauge and inlet hose, a Parweld BuIlDup OF GaS can injure or kill. MIG torch, and a 3.0m work cable with clamp. Digital meters display Shut off shielding gas supply when not in use.
5.3 Input and Grounding Connection WarnInG Before starting the installation, check that your power supply is adequate for the voltage, amperage, phase, and frequency www.parweld.com...
MIG, TIG and Plasma welding torches. 5.7 torch installation The Parweld XTS recirculation equipment can be fitted with a fail- Your Parweld MIG/MAG Welding Torch has been supplied ready to safe flow protection device to prevent overheating or meltdown.
When no more welding is to be done, close valve on gas cylinder (if used), momentarily operate gun trigger to release gas pressure and turn off the machine. 6.2 Optimising weld parameters www.parweld.com...
Page 10
Reduce travel speed. Burn-Through - weld metal Excessive heat input. Select melting lower voltage range and reduce wire feed speed. Completely through base metal Increase and/or maintain Resulting in holes where no steady travel speed. metal remains. www.parweld.com...
9 BSP inlet and outlet connections Stock Code Description 706101 Flow Meter Mixed Gas 25 lpm (MIG) Gas flow Tester • Designed to check gas flow at the front of Mig Torches. Stock Code Description 806001 Gas flow Tester www.parweld.com...
9.0 EC declaration of conformity Hereby we declare that the machines as stated below Type: XTM303C Conform to the EC Directives: Low Voltage Directive 2006/95/EC EMC Directive 2004/108/EC Harmonised European standard: EN/IEC 60974-1 This is to certify that the tested sample is in conformity with all provisions of the above detailed EU directives and product standards.
WEE compliance outside the UK please contact your supplier/Importer Parweld is registered with a compliance scheme Official registration number is WEE/FD0255QV When your equipment reaches the end of its service life you should return it to Parweld where it will be reconditioned or processed for recycling.
Page 18
Parweld Limited Bewdley Business Park Long Bank Bewdley Worcestershire England DY12 2TZ tel. +44 1299 266800 fax. +44 1299 266900 www.parweld.com info@parweld.co.uk...