Honeywell VISTA-20PSeries User Manual page 43

Table of Contents

Advertisement

Words or letters in parentheses ( ) are those that are displayed on Fixed-Word Display
keypads.
Other Trouble
Displays
*
Any "beeping" that
accompanies a
trouble display can
be stopped by
depressing any key
on the keypad or by
entering an OFF
sequence (code +
OFF)
**
Not all systems use
wireless sensors.
Trouble Conditions
COMM. FAILURE
(or FC)
SYSTEM LO BAT
(or BAT with no
zone No.)
LO BAT
+ zone descriptor
(or BAT with
zone No.)
Rcvr Jam
(or CHECK 90)
MODEM COMM
(or CC)
BELL FAILURE
(or CHECK 70)
Indicates that a failure has occurred in
the telephone communication portion of
your system.
CALL FOR SERVICE.
Indicates that a low system battery
condition exists. Display is
accompanied by "beeping"* at the
keypad. If this condition persists for
more than one day (with AC present),
CALL FOR SERVICE.
Indicates that there is a low battery
condition in the wireless transmitter**
number displayed (00 is RF keypad).
Accompanied by a single "beep" * (about
once every 40 seconds) at the keypad.
Either replace the battery yourself, or
CALL FOR SERVICE. If the battery is
not replaced within 30 days, a CHECK
display may occur.
Wireless part of the system is
experiencing
RF interference which may impede
reception from wireless sensors.**
Indicates that the control is on-line with
the Central Monitoring Station's remote
computer.
The control will not operate while on-line.
Wait a few minutes — the display should
disappear.
Indicates that the wiring connection to
the external sounder is at fault (open or
shorted). Accompanied by "beeping" at
the keypad. CALL FOR SERVICE.