NEC Express5800 series User Manual page 179

Hide thumbs Also See for Express5800 series:
Table of Contents

Advertisement

On-screen error message
0B80
BMC Memory Test Failed.
0B81
BMC Firmware Code Area CRC check
failed.
0B82
BMC core hardware failure.
0B83
BMC IBF or OBF check failed.
0B8B BMC progress check timeout
0B8C BMC command access failed.
0B8D Could not redirect the console
- BMC Busy -
0B8E Could not redirect the console
- BMC Error -
0B8F Could not redirect the console
- BMC Parameter Error -
0B90
BMC Platform information Area Corrupted.
0B91
BMC update firmware corrupted.
0B92
Internal Use Area of BMC FRU corrupted
0B93
BMC SDR Repository empty.
0B94
IPMB signal lines do not respond.
0B95
BMC FRU device failure.
0B96
BMC SDR Repository failure.
0B97
BMC SEL device failure.
0B98
BMC RAM test error
0B99
BMC Fatal hardware error.
0B9A Management controller not responding
0B9B Private I2C bus not responding.
0B9C BMC internal exception
0B9D BMC A/D timeout error.
0B9E SDR repository corrupt.
0B9F SEL corrupt.
0BB0 SMBIOS - SROM data read error.
0BB1 SMBIOS - SROM data checksum bad.
0BD0 1st SMBus device address not
acknowledged.
Action
Power off and reboot the server. If the error
persists, contact your service representative.
FRU command and EMP feature are
unavailable. This is not a fatal error, however,
power-off and reboot the server. If the error
persists, contact your service representative.
Power off and reboot the server. If the error
persists, contact your service representative.
Access to SMC via IPMB is unavailable. This is
not a fatal error, however, power-off and reboot
the server. If the error persists, contact your
service representative.
FRU command and EMP feature are
unavailable. This is not a fatal error, however,
power-off and reboot the server. If the error
persists, contact your service representative.
Power off and reboot the server. If the error
persists, contact your service representative.
Troubleshooting 8-7