Message Id: 24748
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that a SAS link error has been detected between
I/O module <module number 1> of box <box number 1> and I/O module <module number
2> of box <box number 2>. These boxes are connected to port <port number> of the
external array controller. Please check this data path and the associated
hardware.
The external Smart Array controller reporting this event is attached to the host
side Smart Array controller <controller name / slot information>.
Message Id: 24749
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that a SAS link error has been detected in bay
<bay number> of box <box number> which is connected to port <port number> of the
external array controller. Please check this data path and the associated
hardware.
The external Smart Array controller reporting this event is attached to the host
side Smart Array controller <controller name / slot information>.

Message identifiers 24750-24774

Message Id: 24750
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that a SAS link error has been detected between
port <port number> and the switch expander connected to this port. Please check
this data path and the associated hardware.
The external Smart Array controller reporting this event is attached to the host
side Smart Array controller <controller name / slot information>.
Message Id: 24751
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that a SAS link error has been detected between
a switch expander and I/O module <module number> of box <box number>. This hardware
is connected to port <port number> of the external array controller. Please check
this data path and the associated hardware.
The external Smart Array controller reporting this event is attached to the host
side Smart Array controller <controller name / slot information>.
Message Id: 24752
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that storage box number <box number> was added
to port <port number>. This connection is through I/O module number <module
number> on the storage box.
HP Smart Array errors 144