Configuring BDR91
Binding BDR91 hot water/heating
relay
• Press and hold the button of the BDR91
relay module for 5 seconds to activate
the bind mode.
The red LED flashing at 0.5s on / 0.5s off
confirms that the bind mode has been
activated.
• Follow the evotouch GUIDED
CONFIGURATION or EXPERT
CONFIGURATION until the following
screen appears.
• Position the evotouch controller as close
as possible to the BDR91 relay module.
• Press the BIND button on the evotouch
controller to send the bind signal to the
BDR91 relay module.
• The red LED of the BDR91 is switched off
to confirm a successful binding.
• The evotouch display shows "The BIND
signal was sent. Press NEXT when
successful or BACK to send again."
• If binding was unsuccessful, repeat
binding procedure.
12
Note: Binding is terminated automatically
after 5 minutes.
After the power up of the BDR91 relay
module the red LED will start to flash at
0.1s on / 0.9s off. If this is not the case,
set the BDR91 into the reset mode (see
instructions BDR91).
Checking RF communication
• The evotouch controller sends test
signals to and from the assigned BDR91
relay module in order to test the signal
strength.
The signal strength can be EXCELLENT,
GOOD, POOR or NOT RECEIVED.