Honeywell evohome Installation Manual page 10

Sundial pack thermostat
Hide thumbs Also See for evohome:
Table of Contents

Advertisement

Configuring CS92A
How to bind CS92A to evotouch
• Hold the CS92A transceiver
(without mounting plate and sensor)
approximately 1 metre from evotouch.
• Put CS92A into binding mode by
pressing and holding the CS92A button
for 5 seconds, until the green light comes
on and the red light flashes once a
second.
• Follow the evotouch GUIDED
CONFIGURATION or EXPERT
CONFIGURATION until the following
screen appears.
• Now press the CS92A button to send the
binding message to evotouch.
• The evotouch display shows "The BIND
signal was received properly. Press
NEXT when successful or BACK to send
again.".
• If binding was successful CS92A will exit
binding mode and both lights will switch
off.
• If binding was unsuccessful, repeat
binding procedure.
10
CS92A signal strength test
Once CS92A is bound to evotouch, the
signal strength test allows the transceiver to
be positioned in the best possible location
for signal reception.
Green light
(under button)
Activate signal strength test on the
CS92A transceiver
Red light
(under button)
• Press the CS92A button once.
• The green light should come on. If it
• With the green light on, the red light
Signal Strength = 5
Signal Strength = 2
evotouch measures the strength of the
CS92A signal every 5 seconds and will
communicate this to CS92A as a number
between 0 and 5. CS92A will then indicate
this number by flashing its red light a
number of times in succession, followed by
a pause of between 2 and 4 seconds. The
number of flashes is equivalent to the signal
strength number.
A signal strength > 2 is recommended to
ensure reliable communication.
doesn't, reinsert the batteries and try
again.
should start to flash to indicate the status.
Green light
(under button)
Red light
(under button)
5 secs

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents