NIGHT CONNECTION-FIXED

NIGHT CONNECTION-FLEXIBLE

PROGRAMMING
To Provide Night Connection Stations:
START
CM30
Assign a Night Connection Station to each in-
coming trunk.
Assign the destination to which a call is for-
warded when the Night Connection Station is
busy/no answer.
CM41
Specify the timing for a call forwarding when
the Connection Station is no answer.
NOTE:
END
DESCRIPTION
This timing is also applied to Call
Forwarding-No Answer, Attendant
Overflow, and Group Diversion.
NIGHT CONNECTION-FIXED/NIGHT CONNECTION-FLEXIBLE
Y=03
(1)
000-255: Trunk No.
(2)
04: Direct-In Termination
Y=05
(1)
000-255: Trunk No.
(2)
X-XXXXXXXX: Night Connection Sta-
Y=14 When Night Connection Station is
busy
(1)
000-255: Trunk No.
(2)
01 : To TAS
04 : To Attendant Console
06 : Automatic Camp-On
15 : Keep the call ringing until the station
becomes idle
Y=16 When Night Connection Station is no
answer
(1)
000-255: Trunk No.
(2)
01 : To Attendant Console
03 : To TAS
15 : Keep the call ringing until the station
answers
Y=0
(1)
01
(2)
01-30: 4-120 seconds
If no data is set, the default setting is 32-36 sec-
onds.
– 538 –
NIGHT SERVICE
DATA
tion No.
(4 second increments)