Table 7 – Wireless Keys Programming (continued)
Step
Wireless Key Function Chart (continued)
(Cont'd)
Manually Start a Relay Action
Manually Stop a Relay Action
Activate Relay as Programmed
in Control
Activate Relay as Programmed
in Control
Activate Access Control Relay
for Partition
n = Device Number programmed in panel to be controlled
Note: Not intended for use with VISTA-128/250 Series.
Press
Repeat this process for the rest of the wireless key loops.
Enter [5]
Wireless Key On-Board Relay Assignment. Program a button
on the wireless key to control the on-board relay.
Note: Any button can control the on-board relay in addition to performing
one of the Loop functions above.
Enter the loop number of the wireless key (1-4).
Enter the desired relay action:
0 = no action
1 = relay off
2 = relay on
Press
Repeat for the wireless key loops where on-board relay control is
desired.
When all loops have been programmed for the wireless key, press
.
The 6152RF automatically displays the next available device
number (one that does not have a serial number).
If you want to program additional wireless keys, repeat the
previous steps. Otherwise, press
Programming Start screen
Press

DELETING, REPLACING, OR EDITING WIRELESS KEYS

Use the following procedure to make changes to wireless keys.
Table 8 – Deleting, Replacing or Editing Wireless Keys
Step
Enter
Within 30 seconds of power up or reboot, press and hold down the
Program
and
Mode
Enter [5].

Wireless Key Editing

Enter the device number for the wireless key you want to edit (1-
8). This must be a device that has its serial number already
programmed in the 6152RF.
To exit without editing the wireless key, press the
To edit the wireless key, press the
Delete
To delete the serial number, press
again.
Action
# + 7 + n (VISTA-10P, VISTA-15P,
VISTA-20P, VISTA-21ip)
# + 8 + n (VISTA-10P, VISTA-15P,
VISTA-20P, VISTA-21ip)
# + 71 (VISTA-50P)
# + 72 (VISTA-50P)
0 (VISTA-50P)
to save function setting.
3 = relay toggles on and off
4 = relay closes for 2 seconds
to save the relay assignment.
to return to the
to exit the 6152RF Program mode.
Action
keys at the same time for 3 seconds.
Note: If the loop is defaulted with a function (e.g.,
Flashes "o-"
Flashes "o" and the loop number.
Once the action is entered, alternately flashes
"o" and the loop number and the relay action
(e.g., alternately flashing "o3" and "4" shows
Loop 3 will close the relay for 2 seconds.)
Flashes "d" followed by the device number.
d1 – d8
"oo" and "- -" flash alternately
"oo, - -" flash alternately
Flashes "d-".
Once the device number is entered, alternately
flashes "d" with the device number; and the
serial number.
key.
key to continue.
, then
, and press
- 5 -
Display
Default Loop Functions (continued)
LOOP 2
Disarm
LOOP 3
LOOP 4
Arm AWAY
Arm STAY
LOOP 1
Close on-board relay
for 2 seconds
• •
• • •
• •
• •
• •
SET
HOUSE
CODE
5804BD / 5804BDV
Arm, Disarm) and also is assigned to activate
the on-board relay, the system performs BOTH
functions.