Table 8 – Deleting, Replacing or Editing Wireless Keys (continued)
Step
Edit
To change any of the programming for the wireless key, refer to
the procedures described in Table 7 for the following changes:.
• To edit the user code, see "Enter [2]"
• To edit the loop functions, see "Enter [4]"
• To edit the on-board relay assignment, "Enter [5]"
Exit
When you have completed editing the wireless keys, press
twice to exit the Program mode.

FUNCTION KEY LABELS

A set of adhesive-backed labels with some typical
function symbols (fire, police, personal emergency)
is provided. These labels can be placed next to the
keys to identify each key's function for the end user
(as determined by the control panel's capability and
programming; see the control's instructions).

TROUBLESHOOTING

The following error messages cause the 6152RF to produce rapid beeps for 5 seconds. The table below describes the error messages
and the corrective actions.
Table 9 – Troubleshooting
Display
Probable Cause
Lb
Low battery in the wireless key
OC
Open circuit
1C
Incompatible connection
Check 09 OR
1.
6152RF Receiver is not
communicating
Check 100 OR
2.
Another device on the keypad
Check 10n*
terminals conflict with this
receiver address.
E8
Too many RF zones programmed
*n = receiver address programmed in VISTA control panel

SPECIFICATIONS

Physical:
4.88"H x 6.934"W x 1.02"D
Displays:
Fixed-Word LCD (backlit).
Sounder:
Piezo-electric [fire alarm is loud, pulsing single
tone; (all Keypads) burglary alarm is loud,
continuous, dual tone].
Range:
200' nominal.
Frequency:
345 MHz
Action
PANIC ALARM STICKERS
800-13067-02
Corrective Action
1.
Replace the battery in the wireless key.
Verify that the Data Out wire is connected properly.
Verify that the control panel is not a First Alert-type control panel.
1.
Verify that the Data In wire is connected properly.
2.
Verify no other devices on the keypad bus are set for receiver
address.
Verify the number of transmitters programmed into the control panel
Wiring:
Voltage:
Relay:
Current:
NFPA-72:
- 6 -
Display
Alternately flashes "d" with the device number;
and "-."
u4
Ln
o-
61x2-FUNCT-KEY-LBLS-07-19-13
Refer to Installation diagram on page 1.
12VDC (power-limited)
Normally-Open, 1 A, 28VDC
105mA (ARMED LED lit, LCD backlight and
sounder on), reduces to 80mA when panel is
operating in standby mode (backlight off).
Compliant