NEC Electra Elite IPK II System User Manual page 712

Hide thumbs Also See for Electra Elite IPK II System:
Table of Contents

Advertisement

Document Revision 4C
Related Features
Central Office Calls, Answering
Central Office Calls, Placing
Direct Inward System Access (DISA)
Tie Lines
Warning Tone for Long Conversation
Programming
14-01-14
Basic Trunk Data Setup – Long Conversation Cutoff
Enable (1)/Disable (0) a trunk user ability to disconnect incoming and outgoing central office
calls automatically.
14-01-15
Basic Trunk Data Setup – Long Conversation Alarm Before Cut Off
Enable (1)/Disable (0) the Long Conversation Alarm for each trunk.
20-06-01
Class of Service for Extensions
Assign a Class of Service (1~15) to extensions.
20-13-02
Class of Service Options (Supplementary Service) – Long Conversation Cutoff
(Incoming)
Enable (1)/Disable (0) the ability of an extension Class of Service to use Long Conversation
Cutoff for incoming calls.
20-13-03
Class of Service Options (Supplementary Service) – Long Conversation Cutoff
(Outgoing)
Enable (1)/Disable (0) the ability of an extension Class of Service to use Long Conversation
Cutoff for outgoing calls.
(default: 0)
20-21-03
System Options for Long Conversation – Long Conversation Cutoff for Incoming Call
Enter the time the system waits before disconnecting incoming trunks (0~64800 seconds).
(default: 0)
20-21-04
System Options for Long Conversation – Long Conversation Cutoff for Outgoing Call
Enter the time the system waits before disconnecting outgoing trunks (0~64800 seconds).
(default: 0)