System Failure to Display a Position Fix

If the receiver does not get a position fix
within about 8 minutes (flashing antenna
mark (1) as shown in the illustration), make
sure there are no overhead obstructions and
then perform the following.
(1) antenna mark
1. Remove the safety lanyard lock clip from
the engine stop button/switch.
2. Remove the front and rear seats (page
158), and rear storage box (page 229). Wait
a few minutes for the engine to ventilate.
3. Disconnect the negative (–) terminal lead
(2) from the battery (3) and wait 1 minute.
Do not disconnect the positive (+) cable. A
spark could ignite fuel vapors that may be
present in the engine compartment.
ENGINE COMPARTMENT
(1)
(2) negative (–) terminal lead (black cover)
(3) battery
System Start-up
(2)
(3)
(cont'd)