D-Link DGS-6600 Series Hardware Installation Manual
D-Link DGS-6600 Series Hardware Installation Manual

D-Link DGS-6600 Series Hardware Installation Manual

Layer 3 chassis ethernet managed switch
Hide thumbs Also See for DGS-6600 Series:
Table of Contents

Advertisement

Hardware Installation Guide
Product Model : DGS-6600 Series
Layer 3 Chassis Ethernet Managed Switch
Release 3.0
6
7
8

Advertisement

Table of Contents
loading

Summary of Contents for D-Link DGS-6600 Series

  • Page 1 Hardware Installation Guide Product Model : DGS-6600 Series Layer 3 Chassis Ethernet Managed Switch Release 3.0...
  • Page 2: Fcc Warning

    Microsoft Corporation. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. D-Link Corporation disclaims any proprietary interest in trademarks and trade names other than its own.
  • Page 3: Table Of Contents

    Safety Recommendations for Removing and replacing Batteries..............ix Safety Precautions for Installing and Removing the Switch................x Electrical Safety ............................x Laser Safety..............................xiii Chapter 1 Introduction ......................1 DGS-6600 Series Switch Description ........................1 DGS-6604 Product Specifications........................1 Product Features ............................1 DGS-6604 Product Appearance ........................3 DGS-6604 Hardware Composition........................4 Chassis .................................4...
  • Page 4 DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Simple Installation Steps..........................40 Mounting the DGS-6600 Series Switch into the Cabinet ...................40 Fan Tray Installation............................41 Power Supply Installation...........................43 Air Filter Installation............................44 System Ground Connection ..........................45 Grounding Precautions ..........................45 Simple Grounding Steps ..........................45 Connecting the AC Power Supply to the Power Module..................46...
  • Page 5 DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide DGS-6600 Series Switch Monitoring Function....................71 Maintaining the DGS-6600 Series Switch Hardware ..................71 Maintaining the DGS-6600 Modules ......................71 Maintaining the Ventilation System.......................71 Maintaining the Power Supply ........................72 Remote Maintenance ............................72 Chapter 7 Troubleshooting....................73 General Flow Chart for Troubleshooting Installation Faults ................73...
  • Page 6: Intended Readers

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Intended Readers The DGS-6600 Series Switch Hardware Installation Guide contains information on how to install the Switch hardware. This manual is intended for network or I.T. managers familiar with network management concepts and terminology.
  • Page 7: Notes, Notices, And Cautions

    DGS-6600 series switch chassis without assistance. • When lifting or handling the DGS-6600 series switch use the lifting handles show in Figure 1. No other parts of the DGS-6600 series switch should be used for lifting or handling.
  • Page 8: Safety Precautions For Installing And Removing The Switch

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide • Replace with the same or equivalent battery type as recommended by the battery manufacturer. • Dispose of the battery in accordance with the battery manufacturers recommendation. Safety Precautions for Installing and Removing the Switch Before moving the chassis, remove all line cards, the fan tray, and all power modules.
  • Page 9 DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide • Avoid carrying out maintenance on the equipment alone when the Switch is powered on. • Before shutting down the power supply, check that it is safe to do so. •...
  • Page 10: Grounding Requirements

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Grounding requirements Proper grounding of the switch will help ensure stable and reliable operation of the DGS-6600 series switch. it is important to verify that the grounding conditions during and after installation of the switch meet the grounding requirements and grounds all devices properly.
  • Page 11: Laser Safety

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Laser Safety A number of the optical modules included in the DGS-6600 series switches are Class I laser products. Therefore, when using these products pay careful attention to the following: •...
  • Page 12: Chapter 1 Introduction

    The D-Link's DGS-6600 series switch is a modular, chassis-based Ethernet backbone switch designed for adaptability and scalability. Currently, the DGS-6600 series chassis is available in a 4-slot chassis (DGS-6604) and 8 slot chassis (DGS-6608). The DGS-6600 Switch provides a management platform with a backplane switch capacity of 576Gbps per Management Module.
  • Page 13 DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide The DGS-6604 includes several features that ensure physical resilience, including multiple redundant power supplies and the capability of hot-swapping line cards or modules in the event of a fault. • Secure Switch Management Methods The DGS-6604 supports several features to prevent non-administrators from logging into the Switch and potentially causing disruption to the network.
  • Page 14: Dgs-6604 Product Appearance

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide DGS-6604 Product Appearance Figure 1-1 DGS-6604 Product Appearance Number Item Name Description Power Layer The built-in power shelf can host up to four power modules. Module Layer The module layer offers 4 module slots. Air Outlet The air outlet is located on the right side of the Switch.
  • Page 15: Dgs-6604 Hardware Composition

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide DGS-6604 Hardware Composition The DGS-6604 hardware consists of a chassis, management card, line cards, power system and a fan system. Chassis The DGS-6604 uses a standard 19-inch chassis, which has a height of 280mm, a width of 484mm, and a depth of 470mm.
  • Page 16: Dgs-6604 Ventilation/Heat Dissipation System

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide DGS-6604 Ventilation/Heat Dissipation System The DGS-6604 operates at a temperature of 0-50ºC. The hardware of the DGS-6604 has been thermally designed so the surface temperature of the components does not exceed the allowed ambient temperature of 50ºC without affecting the reliability, security, and repairability of the Switch.
  • Page 17 DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide • Efficient Data Processing Design The DGS-6608 implements complicated functions, such as switching, routing, ACL, and QoS via the Switch hardware. Using the Switch hardware avoids the issues that can occur when implementing complex functions within software.
  • Page 18: Dgs-6608 Product Appearance

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide DGS-6608 Product Appearance Figure 1-3 DGS-6608 Product Appearance Number Item Name Description Power Layer The built-in power shelf can host up to eight power modules. Module Layer The module layer offers 8 module slots. Air Outlet The air outlet is located on the right side of the Switch.
  • Page 19: Dgs-6608 Hardware Composition

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide DGS-6608 Hardware Composition The DGS-6608 hardware consists of a chassis, management card, line cards, power system and a fan system. Chassis The DGS-6608 uses a standard 19-inch chassis. The chassis consists of the system module layer, fan layer, and power layer.
  • Page 20: Dgs-6608 Ventilation/Heat Dissipation System

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide DGS-6608 Ventilation/Heat Dissipation System The DGS-6608 operates at a temperature of 0-50ºC. The hardware of the DGS-6608 has been thermally designed so the surface temperature of the components does not exceed the allowed ambient temperature of 50ºC without affecting the reliability, security, and repairability of the Switch.
  • Page 21: Dgs-6600 Cpu & I/O Modules

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide DGS-6600 CPU & I/O Modules The DGS-6604/6608 supports the modules described below: DGS-6600-CM: The DGS-6600-CM is a CPU module for the DGS-6604 Series. The CPU module is used to manage the entire system, including layer 2 and layer 3 processes, controlling and managing user access, managing routes, and maintenance on the network and operations.
  • Page 22: Dgs-6600-Cm Module

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide DGS-6600-CM Module The basic appearance of the DGS-6600-CM management module is shown in Figure 1-5. The DGS-6600-CM management module is designed to manage all features of the DGS-6604 model including: system switching, controlling user access, managing user access, controlling the system status, managing routing, controlling maintenance on the network and controlling network operations.
  • Page 23 DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide LEDs The DGS-6600-CM uses different colored LEDs to indicate different systems status, as described in Table 1-3. LED Indicator Color and Status Description Power Solid Green This LED will light solid green when the Switch is powered on. This LED will remain off when the Switch is powered off.
  • Page 24: Technical Specifications

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Technical Specifications Item Description Standard Management port supports IEEE802.3, IEEE802.3u, IEEE802.3ab Half/Full-duplex support Compliance Management Mode Telnet Web-based Port Type 1x Female DCE RS-232 DB-9 console port 1x Female USB series type B console port 1x RJ-45 management port Power System...
  • Page 25: Dgs-6600-Cm-Ii Management Module

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide DGS-6600-CM-II management module: The basic appearance of the DGS-6600-CM-II management module is shown in Figure 1-6. The DGS-6600-CM- II management module is designed to manage all features of the DGS-6608 Switch including: system switching, controlling user access, managing user access, controlling the system status, managing routing, controlling maintenance on the network and controlling network operations.
  • Page 26 DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide LEDs The DGS-6600-CM-II uses different colored LEDs to indicate different systems status, as described in Table 1-5. LED Indicator Color and Status Description Power Solid Green This LED will light solid green when the Switch is powered on. This LED will remain off when the Switch is powered off.
  • Page 27 DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Technical Specifications Item Description Standard Management port supports IEEE802.3, IEEE802.3u, IEEE802.3ab Half/Full-duplex support Compliance Management Mode Telnet Web-based Port Type 1x Female DCE RS-232 DB-9 console port 1x Female USB series type B console port 1x RJ-45 management port Power System...
  • Page 28: Dgs-6600-24Sc2Xs Module

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide DGS-6600-24SC2XS Module The basic appearance of the DGS-6600-24SC2XS module is shown in Figure 1-7. The DGS-6600-24SC2XS is a line card module of the DGS-6604, which provides 12 SFP ports, 12 combo ports (10/100/1000Base-T/SFP Module) and 2 SFP+ ports.
  • Page 29 DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Technical Specifications Item Compliance Standard IEEE 802.3 Compliance IEEE 802.3ab IEEE 802.3ae IEEE 802.3aq IEEE 802.3u IEEE 802.3z Full-duplex support/Half-duplex support (IEEE 802.3x Flow Control support for Full-Duplex mode) SFF-8431 compliant transceiver support Port Type 12 SFP ports, 12 combo ports (10/100/1000Base-T/SFP Module) and 2 SFP+ ports.
  • Page 30: Dgs-6600-16Xs-D

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide DGS-6600-16XS-D The basic appearance of the DGS-6600-16XS-D module is shown in Figure 1-8. The DGS-6600-16XS-D is a line card module of the DGS-6604/6608, which provides 16x 10G SFP+ ports. Figure 1-8 Basic Appearance of the DGS-6600-16XS-D Interface The DGS-6600-16XS-D features 16x 10G SFP+ ports LEDs...
  • Page 31 DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Technical Specifications Item Compliance Standard IEEE 802.3 Compliance IEEE 802.3ab IEEE 802.3ae IEEE 802.3aq IEEE 802.3u IEEE 802.3z Full-duplex support/Half-duplex support (IEEE 802.3x Flow Control support for Full-Duplex mode) SFF-8431 compliant transceiver support Port Type 16 x 10G SFP+ ports.
  • Page 32: Dgs-6600-48P Module

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide DGS-6600-48P Module The basic appearance of the DGS-6600-48P module is shown in Figure 1-9. The DGS-6600-48P is a line card module of the DGS-6604/6608, which features 48x10/100/1000 RJ-45 and POE ports. Figure 1-9 Basic Appearance of DGS-6600-48P...
  • Page 33 DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide LEDs The DGS-6600-48P uses different colored LEDs to indicate different systems status, as described in Table 1-11. Color and Status Description Indicator Power Solid Green This LED will light solid green when the Switch is powered on. This LED will remain off when the Switch is powered off.
  • Page 34 DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Technical Specifications Item Compliance Standard IEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3af, Half/full-duplex support Compliance Port Type 48x 10/100/1000 Mbps PoE ports Power System Hot Swap Supported Ability Power 873 Watts Consumption EMC (Class A):...
  • Page 35: Dgs-6600-48S Module

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide DGS-6600-48S Module The basic appearance of the DGS-6600-48S module is shown in Figure 1-10. The DGS-6600-48S is a line card module of the DGS-6604/6608, which provides 48x SFP modules. Figure 1-10 Basic Appearance of DGS-6600-48S Interface The DGS-6600-48S features 48x SFP modules.
  • Page 36 DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Technical Specifications Item Compliance Standard IEEE 802.3z Compliance Full-duplex support Port Type 48x SFP modules Power System Hot Swap Supported Ability Power 118.6 Watts Consumption EMC (Class A): FCC Part 15, CSA C108.8, 89/336/EEC, EN 55022, EN 61000-3-2, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11, EN 55024, AS/NZS 3548, VCCI V-3.
  • Page 37: Dgs-6600-48T Module

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide DGS-6600-48T Module The basic appearance of the DGS-6600-48T module is shown in Figure 1-11. The DGS-6600-48T is a line card module of the DGS-6604/6608, which provides 48x10/100/1000 Base-T ports. Figure 1-11 Basic Appearance of DGS-6600-48T Interface The DGS-6600-48T features 48x10/100/1000 RJ-45 ports.
  • Page 38 DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Technical Specifications Item Compliance Standard IEEE 802.3, IEEE 802.3u, IEEE 802.3ab Compliance Half/Full-duplex Support Port Type 48x 10/100/1000 Mbps RJ-45 ports Power System Hot Swap Supported Ability Power 109.8 Watts Consumption EMC (Class A): FCC Part 15, CSA C108.8, 89/336/EEC, EN 55022, EN 61000-3-2, EN 61000-3-3, EN...
  • Page 39: Dgs-6600-48Ts Module

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide DGS-6600-48TS Module The basic appearance of the DGS-6600-48TS module is in Figure 1-12. The DGS-6600-48TS is a line card module of the DGS-6604/6608, which provides 24x 10/100/1000 Base-T ports and 24x SFP module ports. Figure 1-12 Basic Appearance of DGS-6600-48TS Interface The DGS-6600-48TS provides 24x 10/100/1000 Base-T ports and 24x SFP module ports.
  • Page 40 DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide LEDs The DGS-6600-48TS uses different colored LEDs to indicate different systems status, as described in Table 1- Color and Status Description Indicator Power Solid Green This LED will light solid green when the Switch is powered on. This LED will remain off when the Switch is powered off.
  • Page 41 DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Technical Specifications Item Compliance Standard IEEE: 802.3, 802.3u, 802.3ab, 802.3z, 802.3x flow control support for full-duplex mode Compliance Half/full-duplex support Port Type 24x 10/100/1000 Mbps ports, 24x SFP modules Power System Hot Swap Supported...
  • Page 42: Dgs-6600-8Xg Module

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide DGS-6600-8XG Module The basic appearance of the DGS-6600-8XG module is shown in Figure 1-13. The DGS-6600-8XG is a line card module of the DGS-6604, which provides 8x 10 Gigabit Ethernet XFP module ports. Figure 1-13 Basic Appearance of DGS-6600-8XG Interface The DGS-6600-8XG features 8x 10 Gigabit Ethernet XFP module ports.
  • Page 43 DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Technical Specifications Item Compliance Standard IEEE 802.3ae, Compliance Full-duplex support XFP MSA compliant transceiver support Port Type 8x 10G XFP modules Power System Hot Swap Supported Ability Power 200.26 Watts Consumption EMC (Class A): FCC Part 15, CSA C108.8, 89/336/EEC, EN 55022, EN 61000-3-2, EN 61000-3-3, EN...
  • Page 44: Chapter 2 Installation

    Cable Management Installation Checks Installation Site Requirements The DGS-6600 series switch should be used indoors. To ensure normal operating conditions and prolong the life of the Switch, the following conditions should be met. Rack Mounting Requirements If rack mounting the DGS-6600 series switch, the rack mounting should meet the following requisites: •...
  • Page 45: Ventilation Requirements

    DGS-6608. To ensure normal ventilation, please allow sufficient space at the ventilation openings of the DGS-6600 series switch. After connecting cables to the DGS-6600 series switch, ensure that the cables are arranged in bundles and are positioned so that they don’t block the Switch's air inlets.
  • Page 46: Power Requirements

    Switch. The DGS-6600 Series Switch requires a good grounding system to ensure stable and reliable operations. The grounding system is an important factor in preventing damage from electrical discharges or resistance interference.
  • Page 47: Emi Considerations

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide lightning discharge ground is only used by the lightning protection system and is irrelevant for the rest of the switch system. Figure 2-3 Diagram showing the schematic for the grounding points at the back of the DGS-6604 The power cables that the Switch uses must ensure normal operation.
  • Page 48: Precautions For Fiber Connections

    Switch should connect to the Rx side of the switch at the remote end and the same vice versa. Also note that only class 1 Optical Transceivers can be plugged into the SFP ports of the DGS-6600 series Modules supporting SFP ports.
  • Page 49: Installation Flowchart

    Installation Flowchart Verifying the Installation When planning the DGS-6600 Series installation, please consider the following points: the installation location, the mode of networking that will be used, the power supply requirements and the network cabling requirements. The following should be verified before installing the DGS-6600 Series Switch: •...
  • Page 50: Installing The Cabinet

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide • Does the intended installation location have a power supply that meets the Switch requirements and does the intended location have the appropriate rated AC requirements. • The intended installation location has the required network cabling installed. Installing the Cabinet Cabinet Installation Precautions Please follow the recommendations below when installing the cabinet:...
  • Page 51: Simple Installation Steps

    3. Fit the appropriate chute and cables. 4. Fit the appropriate accessories to the cabinet. Mounting the DGS-6600 Series Switch into the Cabinet Cabinet Mounting Precautions Please verify that the front and rear brackets of the cabinet are in the right locations before mounting the DGS-6600 Switch into the cabinet.
  • Page 52: Fan Tray Installation

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Fan Tray Installation The DGS-6600-FAN fan tray is used by the DGS-6600 Series Switch as a ventilation system. Follow the instructions below to correctly install the fan tray: 1. Use the thumb-screws to remove the fan tray blank panel.
  • Page 53 DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Figure 2-5 Schematic diagram for installing the fan tray in the DGS-6608...
  • Page 54: Power Supply Installation

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Power Supply Installation The procedure for installing the AC power supply is shown in the diagram 2-4: Figure 2-6 Schematic diagram for installing an AC power supply Figure 2-7 Schematic diagram for installing an AC power supply...
  • Page 55: Air Filter Installation

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Air Filter Installation On the back of the chassis on the edge of the right-side is a vertical slot where the air filter can be fitted. Slide in a cleaned or new air filter into the slot, please see figure 2-5. Screw the two thumb-Phillips screws (see Figure 2- 5 diagram arrows) securing the air filter into the chassis.
  • Page 56: System Ground Connection

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide System Ground Connection The back of the DGS-6604 has two working ground connections on its back panel. The grounds must be well treated to provide adequate protection for the system. The grounding connections must be directly connected to the ground pole or the ground bar of the equipment room.
  • Page 57: Connecting The Ac Power Supply To The Power Module

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Connecting the AC Power Supply to the Power Module Use the AC power cable to connect to the AC power module panel, as indicated in Figure 2-6: Figure 2-10 Connecting the DGS-6604 to an AC power supply connection AC Power Supply Connection Precautions •...
  • Page 58: Connecting The Management Module Cable

    NOTE: The DGS-6600 must have a management module installed to operate. Removing Line Cards from the DGS-6600 Series Switch Carry out the following steps to remove boards from the DGS-6600 series switch: 1. Please save current configuration. 2. Unplug all copper/fiber cabling, i.e. RJ45 twisted-pair and fiber optic cables, from the board that you want to remove.
  • Page 59: Installing Line Cards In The Dgs-6600 Series Switch

    Figure 2-11 Schematic diagram for removing a line card Installing Line Cards in the DGS-6600 Series Switch Carry out the following steps to install boards in the DGS-6600 Series Switch: 1. Remove the component card or blank panel as instructed in the section Removing Line Cards from the DGS-6600.
  • Page 60 DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Figure 2-12 Schematic diagram for installing a line card...
  • Page 61: Connecting The External Interface Cables

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Connecting the External Interface Cables Connecting External Interface Cable Precautions • Ensure that you correctly distinguish between single-mode and multi-mode fibers and interfaces. • Avoid small radius bends at the connector. Simple External Interface Cable Connection Steps 1.
  • Page 62: Installation Checks

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Installation Checks Checking the Cabinet • Ensure that the external power supply corresponds with cabinet’s distribution panel. • Check that the cabinet door can close properly after all the equipment has been installed. •...
  • Page 63: Chapter 3 Connecting The Switch

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Chapter 3 Connecting the Switch Switch to End Node Chassis to Switch Connecting To Network Backbone or Server Connecting the Management Module Cable Connecting the External Interface Cables Switch to End Node Please note that while this chapter uses diagrams of the DGS-6604, the same techniques will apply to all DGS- 6600 Series Switches.
  • Page 64: Chassis To Switch

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Chassis to Switch There is a great deal of flexibility on how connections are made using the appropriate cabling. "Connect a 10BASE-T switch port to the Switch via a twisted-pair Category 3, 4 or 5 UTP/STP cable. "Connect a 100BASE-TX switch port to the Switch via a twisted-pair Category 5 UTP/STP cable.
  • Page 65: Connecting To Network Backbone Or Server

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Connecting To Network Backbone or Server The combo SFP ports and the 1000BASE-T ports are ideal for uplinking to a network backbone, server or server farm. The copper ports operate at a speed of 1000, 100 or 10Mbps in full or half duplex mode. The fiber-optic ports can operate at both 100Mbps and 1000Mbps in full duplex mode.
  • Page 66: Connecting The Management Module Cable

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Connecting the Management Module Cable Refer to Connecting the Console Port on page 57 Connecting the External Interface Cables Connecting External Interface Cable Precautions • Ensure that you correctly distinguish between single-mode and multi-mode fibers and interfaces. •...
  • Page 67: Chapter 4 Introduction To Switch Management

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Chapter 4 Introduction to Switch Management Management Options Connecting the Console Port First Time Connecting to the Switch Connecting to the Ethernet Management Port Password Protection Saving Configuration Changes SNMP Settings Management Options The system can be Command Line managed, out-of-band, through either the serial console ports (RS-232/USB) or the Management Ethernet port (Telnet) which is located on the front of the command module.
  • Page 68: Command Line Interface Through The Serial Ports

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Command Line Interface through the Serial Ports Users can also connect a computer or terminal to one of the serial console ports (USB or RS-232) to access the Switch. The command line interface provides complete access to all Switch management features. The following section provides details on how to setup this connection.
  • Page 69 DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide • Select Terminal keys for Function, Arrow and Ctrl keys. Make sure to use Terminal keys (not Windows keys) are selected. NOTE: When using HyperTerminal with the Microsoft® Windows® 2000 operating system, ensure that Windows 2000 Service Pack 2, or later, is installed.
  • Page 70 ... isr ... eeprom ... bspmgt ... bspioctl ... cf ... devinfo ... Initializing: path setting Initializing: ASICdriver-1 kernel bde ... Initializing: protocol stack Initializing: Initializing: wait runtime images sync ... Figure 4-1 DGS-6600 Series Switch initial boot messages...
  • Page 71: First Time Connecting To The Switch

    DGS-6600 Chassis-based High-Speed Switch Command Line Interface Firmware: 3.00.048 Copyright (c) 2012 D-Link Corporation. All rights reserved. DGS-6600:2> Figure 4-2 Initial screen first time connecting to the switch There is no initial login procedure until at least one user is created through the CLI Command Interface. The Switch will automatically login to the User Exec level.
  • Page 72: Connecting To The Ethernet Management Port

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Connecting to the Ethernet Management Port The front panel of the CM Module features an out-of-band Ethernet Management port. The port is an RJ-45 port that can be easily connected to a notebook computer using a standard Ethernet cable. Connect to the port for out-of-band management using a Telnet command line interface.
  • Page 73: Password Protection

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide The Switch CM is assigned a unique MAC address by the factory. This MAC address cannot be changed, and can be found by entering the command show system into the command line interface. The MAC address of the CM management ethernet port can be seen below in the information section for Slot 1 DGS-6600:15(mgmt-if)#show system Device Type...
  • Page 74: Saving Configuration Changes

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide When creating a user account, the user can specify if the password will be entered in an encrypted or plain text form. If a password is entered into the Switch in plain-text form, but the password encryption function is enabled; the password will be converted to encrypted form.
  • Page 75: Traps

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide SNMP v.3 uses a more sophisticated authentication process that is separated into two parts. The first part is to maintain a list of users and their attributes that are allowed to act as SNMP managers. The second part describes what each user on that list can do as an SNMP manager.
  • Page 76: Chapter 5 Web-Based Switch Management

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Chapter 5 Web-based Switch Management Introduction Enabling and Configuring the Web User Interface Logging onto the Web Manager Web-based User Interface (Web UI) Configuring the Management Interface using the Web UI Introduction Some of the software functions of the Switch can be managed, configured, and monitored via the embedded web-based (HTML) interface.
  • Page 77: Enabling And Configuring The Web User Interface

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Enabling and Configuring the Web User Interface To re-enable the Web interface after it has been disabled by the user, enter the following CLI commands in privileged EXEC mode: DGS-6600:2>enable DGS-6600:15#configure terminal DGS-6600:15(config)#ip http server DGS-6600:15(config)#end...
  • Page 78: Logging Onto The Web Manager

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Logging onto the Web Manager To begin managing the Switch, simply run the browser installed on your computer. Use the IP address you have defined for the device. The URL in the address bar should read something like: http://123.123.123.123, where the numbers 123 represent the IP address of the Switch.
  • Page 79: Areas Of The User Interface

    Click the D-Link logo to go to the D-Link Website. Select the Refresh Interval time from the drop down menu on the right and then click the Apply button to set the interval when the specific modules LED’s will be updated in the graphical view.
  • Page 80: Configuring The Management Interface Using The Web Ui

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Configuring the Management Interface using the Web UI 1. In the folder window expand the Configuration folder by clicking on the Plus (+) symbol to the left. 2. Then click on the Management Interface item in the newly expanded list. 3.
  • Page 81: Chapter 6 Maintenance

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Chapter 6 Maintenance DGS-6600 Series Switch Monitoring Function Maintaining the DGS-6600 Series Switch Hardware Remote Maintenance...
  • Page 82: Dgs-6600 Series Switch Monitoring Function

    DGS-6600 Series Switch Monitoring Function Each board installed in the DGS-6600 Series Switch features a System LED, which can be used to monitor the status of each board while the Switch is running. If the System LED on a line card is red, a fault has occurred on the line card and some diagnostics will need to be carried out to establish the route cause.
  • Page 83: Maintaining The Power Supply

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Maintaining the Power Supply Carry out the following to replace a faulty power supply: Hold the power cable and gently pull the cable clip to the left to release the cable from the cable clip. Disconnect the power cable from the power supply.
  • Page 84: Chapter 7 Troubleshooting

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Chapter 7 Troubleshooting General Flow Chart for Troubleshooting Installation Faults Common Troubleshooting Procedures General Flow Chart for Troubleshooting Installation Faults...
  • Page 85: Common Troubleshooting Procedures

    The Switch’s system login password has been forgotten or lost, making it impossible to login and configure the Switch. Troubleshooting: To resolve this issue please contact the D-Link Customer Service Department for technical support. Fault 2: The AC power module is not working. Description: The System LED of each line card is OFF, the power module LED is OFF, the fan tray LEDs are OFF, and the fans are not working.
  • Page 86: Troubleshooting

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Fault 4: The LEDs on a line card start to behave strangely after the line card has been working for a while. Description: The line card’s Status LED suddenly turns OFF, starts to flash, or lights RED. The line card’s Link/Act LED lights solidly when no network cable or fiber optic cable is plugged in.
  • Page 87 DGS-6600 Configuration Guide R3, modify the serial port parameters so that it matches. If this does not solve the problem, please contact the D-Link Customer Service Department for technical support. Fault 8: Illegible characters appear in the serial port console.
  • Page 88: Technical Specifications 6604

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Appendix A Technical Specifications Technical Specifications 6604 General Module slots 4 (1 slot for the CPU Management Module and 3 for Line Cards) Number of supported VLANs 4095 VLAN groups Layer 2 protocols IEEE: 802.3, 802.3u, 802.3z, 802.3ae, 802.3x, 802.3af, 802.3ab, 802.1X RSPAN, IGMP Snooping, Jumbo Frame (1,536-9,728 bytes), GVRP, STP/...
  • Page 89 DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Environment EMC (Class A): • FCC Part 15 • CSA C108.8 • 89/336/EEC • EN 55022 • EN 61000-3-2 • EN 61000-3-3 • EN 61000-4-2 • EN 61000-4-3 • EN 61000-4-4 •...
  • Page 90: Technical Specifications 6608

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Power Supply / Fan Power Supply Rated voltage : 110 VAC 220 VAC Tolerance range : 90~264 VAC Power consumption: 853.5 W/set Heat Dissipation: 2912.4 BTU/hr@110V 2912.4 BTU/hr@220V Power Supply Redundancy Supported - all power supplies must be of the same type (AC only).
  • Page 91 DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide I/O Module DGS-6600-48T, DGS-6600-48S, DGS-6600-48TS, DGS-6600-48P, DGS- 6600-16XS-D Fan Tray DGS-6600-FAN-II Hot-swap ability Supported on all cards...
  • Page 92 DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Environment EMC (Class A): • FCC Part 15 • CSA C108.8 • 89/336/EEC • EN 55022 • EN 61000-3-2 • EN 61000-3-3 • EN 61000-4-2 • EN 61000-4-3 • EN 61000-4-4 •...
  • Page 93 DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Power Supply / Fan Power Supply Rated voltage : 110 VAC 220 VAC Tolerance range : 90~264 VAC Power consumption: 853.5 W/set Heat Dissipation: 2912.4 BTU/hr@110V 2912.4 BTU/hr@220V Power Supply Redundancy Supported - all power supplies must be of the same type (AC only).
  • Page 94: Connection Modules

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Connection Modules The DGS-6600 series switch supports several types of SFP and XFP modules to suit the requirements of the user’s network. The tables below list the available SFP and XFP modules.
  • Page 95: 1000Base-T/100Base-Tx/10Base-T Port

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Appendix B Connectors and Connection Media 1000BASE-T/100BASE-TX/10BASE-T Port A 1000BASE-T/100BASE-TX/10BASE-T port is a port that can automatically adjust between three different speed rates and automatically determine whether to operate in MDI or MDIX crossover mode. In order to take advantage of the 1000BASE-T speed rate, the user needs to use CAT5e or higher cabling, which supports a maximum length of 100M.
  • Page 96: Optical Fiber Connection

    DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide Figure B-1 Straight-Through Vs Crossover Schematic Diagram for the four twisted pair required for 10BASE-T/100BASE-TX Optical Fiber Connection If using fiber-optic ports, be sure to select the correct fibre cables. Fiber modules can use either single-mode or multi-mode fibre cables.

This manual is also suitable for:

Dgs-6604Dgs-6608

Table of Contents