Makita 8270D Instruction Manual page 3

Cordless percussion-driver drill
Hide thumbs Also See for 8270D:
Table of Contents

Advertisement

For Model 8390D
For European countries only
Noise
The typical A-weighted noise level determined according
to EN60745:
Sound pressure level (L
Uncertainty (K) : 3 dB(A)
The noise level under working may exceed 80 dB (A).
Wear ear protection.
Vibration
The
vibration
total
determined according to EN60745-2-1:
Work mode: impact drilling into concrete
Vibration emission (a
Uncertainty (K) : 1.5 m/s
Work mode : drilling into metal
Vibration emission (a
Uncertainty (K) : 1.5 m/s
The declared vibration emission value has been
measured in accordance with the standard test
method and may be used for comparing one tool
with another.
The declared vibration emission value may also be
used in a preliminary assessment of exposure.
WARNING:
The vibration emission during actual use of the
power tool can differ from the declared emission
value depending on the ways in which the tool is
used.
Be sure to identify safety measures to protect the
operator that are based on an estimation of
exposure in the actual conditions of use (taking
account of all parts of the operating cycle such as
the times when the tool is switched off and when it
is running idle in addition to the trigger time).
EC Declaration of Conformity
We
Makita
Corporation
manufacturer declare that the following Makita
machine(s):
Designation of Machine: Cordless Percussion-Driver
Drill
Model No./ Type: 8270D,8280D,8390D
are of series production and
Conforms to the following European Directives:
98/37/EC until 28th December 2009 and then with
2006/42/EC from 29th December 2009
) : 80 dB(A)
pA
value
(tri-axial
vector
2
) : 7.5 m/s
h,ID
2
2
) : 2.5 m/s
or less
h,D
2
as
the
responsible
And are manufactured in accordance with the following
standards or standardised documents:
EN60745
ENG104-1
The technical documentation is kept by our authorised
representative in Europe who is:
Makita International Europe Ltd,
Michigan, Drive, Tongwell,
Milton Keynes, MK15 8JD, England
ENG203-1
000230
sum)
ENG302-2
General Power Tool Safety
Warnings
ENG901-1
WARNING Read all safety warnings and all
instructions. Failure to follow the warnings and
instructions may result in electric shock, fire and/or
serious injury.
Save all warnings and
instructions for future reference.
The term "power tool" in the warnings refers to your
mains-operated (corded) power tool or battery-operated
(cordless) power tool.
Work area safety
1.
Keep work area clean and well lit. Cluttered or
dark areas invite accidents.
2.
Do not operate power tools in explosive
atmospheres, such as in the presence of
flammable liquids, gases or dust. Power tools
create sparks which may ignite the dust or fumes.
3.
Keep children and bystanders away while
ENH101-12
operating a power tool. Distractions can cause
you to lose control.
Electrical safety
4.
Power tool plugs must match the outlet. Never
modify the plug in any way. Do not use any
adapter plugs with earthed (grounded) power
tools. Unmodified plugs and matching outlets will
reduce risk of electric shock.
5.
Avoid body contact with earthed or grounded
surfaces such as pipes, radiators, ranges and
refrigerators. There is an increased risk of
electric shock if your body is earthed or grounded.
3
30th January 2009
Tomoyasu Kato
Director
Makita Corporation
3-11-8, Sumiyoshi-cho,
Anjo, Aichi, JAPAN
GEA006-2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

8280d8390d