Cisco Catalyst 3750-X Command Reference Manual page 820

Cisco ios release 15.2(1)e and later
Hide thumbs Also See for Catalyst 3750-X:
Table of Contents

Advertisement

show power inline
Gi1/0/5
Gi1/0/6
Gi1/0/7
Gi1/0/8
Gi1/0/9
Gi1/0/10
Gi1/0/11
Gi1/0/12
Gi1/0/13
<output truncated>
In the previous example:
The Gi1/0/1 port is shut down, and policing is not configured.
The Gi1/0/2 port is shut down, but policing is enabled with a policing action to generate a syslog
message.
The Gi1/0/3 port is shut down, but policing is enabled with a policing action is to shut down the port.
Device detection is disabled on the Gi1/0/4 port, power is not applied to the port, and policing is
disabled.
Device detection is disabled on the Gi1/0/5 port, and power is not applied to the port, but policing
is enabled with a policing action to generate a syslog message.
Device detection is disabled on the Gi1/0/6 port, and power is not applied to the port, but policing
is enabled with a policing action to shut down the port.
The Gi1/0/7 port is up, and policing is disabled, but the switch does not apply power to the connected
device.
The Gi1/0/8 port is up, and policing is enabled with a policing action to generate a syslog message,
but the switch does not apply power to the powered device.
The Gi1/0/9 port is up and connected to a powered device, and policing is disabled.
The Gi1/0/10 port is up and connected to a powered device, and policing is enabled with a policing
action to generate a syslog message. The policing action does not take effect because the real-time
power consumption is less than the cutoff value.
The Gi1/0/11 port is up and connected to a powered device, and policing is enabled with a policing
action to generate a syslog message.
The Gi1/0/12 port is up and connected to a powered device, and policing is enabled with a policing
action to shut down the port. The policing action does not take effect because the real-time power
consumption is less than the cutoff value.
The Gi1/0/13 port is up and connected to a powered device, and policing is enabled with a policing
action to shut down the port.
This is an example of output from the show power inline police interface-id command on a standalone
switch.
Switch> show power inline police gigabitethernet0/4
Interface Admin
--------- ------ ---------- ---------- ---------- ------ -----
Gi0/4
Table 2-47
Field
Available
Catalyst 3750-X and 3560-X Switch Command Reference
2-788
off
off
log
off
off
errdisable n/a
auto
off
none
auto
off
log
auto
on
none
auto
on
log
auto
on
log
auto
on
errdisable ok
auto
errdisable
errdisable n/a
Table 2-47
describes the output fields.
Oper
Admin
State
State
Police
auto
power-deny log
show power inline police Field Descriptions
Description
The total amount of configured power
Chapter 2 Catalyst 3750-X and 3560-X Switch Cisco IOS Commands
n/a
5.4
0.0
5.4
0.0
n/a
n/a
0.0
n/a
5.4
0.0
n/a
n/a
5.1
ok
5.4
4.2
log
5.4
5.9
5.4
4.2
5.4
0.0
Oper
Cutoff Oper
Police
Power
Power
n/a
4.0
0.0
1
on the switch in watts (W).
OL-29704-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 3560-x

Table of Contents