Chapter 2 Catalyst 3750-X and 3560-X Switch Cisco IOS Commands
Command Modes
Privileged EXEC
Command History
Release
12.2(53)SE2
Usage Guidelines
When OBFL is enabled, the switch records OBFL data in a continuous file that contains all of the data.
The continuous file is circular. When the continuous file is full, the switch combines the data into a
summary file, which is also known as a historical file. Creating the summary file frees up space in the
continuous file so that the switch can write newer data to it.
When using the module switch-number parameter, follow these guidelines:
Use the start and end keywords to display data collected only during a particular time period. When
specifying the start and end times, follow these guidelines:
Examples
This is an example of output from the show logging onboard clilog continuous command:
Switch# show logging onboard clilog continuous
--------------------------------------------------------------------------------
CLI LOGGING CONTINUOUS INFORMATION
--------------------------------------------------------------------------------
MM/DD/YYYY HH:MM:SS COMMAND
--------------------------------------------------------------------------------
05/12/2006 15:33:17 show logging onboard temperature detail
05/12/2006 15:33:21 show logging onboard voltage detail
05/12/2006 15:33:32 show logging onboard poe detail
05/12/2006 16:14:09 show logging onboard temperature summary
...
<output truncated>
....
05/16/2006 13:07:53 no hw-module module logging onboard message level
05/16/2006 13:16:13 show logging onboard uptime continuous
05/16/2006 13:39:18 show logging onboard uptime summary
05/16/2006 13:45:57 show logging onboard clilog summary
--------------------------------------------------------------------------------
OL-29704-01
Modification
This command was introduced.
On a Catalyst 3750-X switch, if you enter the module keyword but do not enter the switch number,
the switch displays OBFL information about the stack members that support OBFL.
On a Catalyst 3560-X switch, if you enter the module keyword, you must enter the switch-number
value of 1.
hh:mm:ss—Enter the time as a 2-digit number for a 24-hour clock. Make sure to use the colons (:).
For example, enter 13:32:45.
day—Enter the day of the month. The range is from 1 to 31.
month—Enter the month in upper case or lower case letters. You can enter the full name of the
month, such as January or august, or the first three letters of the month, such as jan or Aug.
year—Enter the year as a 4-digit number, such as 2008. The range is from 1993 to 2035.
Catalyst 3750-X and 3560-X Switch Command Reference
show logging onboard
2-717