Troubleshooting - Honeywell FocusPRO 6000 Series User Manual

Programmable digital thermostat
Hide thumbs Also See for FocusPRO 6000 Series:
Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting

If you have difficulty with your thermostat, please try the following suggestions.
Most problems can be corrected quickly and easily.
Display is
blank
Heating
or cooling
system does
not respond
Temperature
settings do
not change
"Cool On" or
"Heat On" is
flashing
To restore
default
settings
• Check circuit breaker and reset if necessary.
• Make sure power switch at heating & cooling system is
on.
• Make sure furnace door is closed securely.
• Make sure fresh AA alkaline batteries (depending on
model) are correctly installed (see page 6).
• Press SYSTEM button to set system Heat (see page 2).
Make sure the temperature is set higher than the Inside
temperature.
• Press SYSTEM button to set system to Cool (see page 2).
Make sure the temperature is set lower than the Inside
temperature.
• Check circuit breaker and reset if necessary.
• Make sure power switch at heating & cooling system is
on.
• Make sure furnace door is closed securely.
• Wait 5 minutes for the system to respond.
Make sure heating and cooling temperatures are set to
acceptable ranges:
• Heat: 40° to 90°F (4.5° to 32°C).
• Cool: 50° to 99°F (10° to 37°C).
• Compressor protection feature is engaged. Wait 5
minutes for the system to restart safely, without damage
to the compressor (see page 5).
Follow these steps to restore default settings:
1. Press SET CLOCK/DAY/SCHEDULE.
2. Press SET SCHEDULE.
3. Press DONE and NEXT at the same time for 4 seconds.
7

Hide quick links:

Advertisement

Table of Contents
loading