Advance Planning
ADVANCE PLANNING
Ductwork
Planning
,This hood is equipped for 8" round ductwork.
, Determine the exact locution of the vent hood.
, Plan the route for venting exhaust to the outdoors.
This hood is not designed for e recirculeting
venting operation.
, Use the shortest end straightest
duct route
possible. For satisfactory
performance,
duct run
should not exceed 100 ft. equivalent length for any
duct configurations.
, Refer to "Duct Fittings" chert to compute
the
maximum
permissible
length for duct runs to the
outdoors.
, Use rigid metal ductwork
only.
,install
e well or roof cup with damper at the
exterior opening. Order the cop end any transitions
needed in advance.
Wall and Ceiling Framing for Adequate
Support
This vent hood is heavy and the cabinet structure
needs to support the weight of the loaded insert
sleeve. Adequate structural
support must be
provided in all types of installations.
• Installation will be easier if the vent hood is
installed before the cooktop is installed.
Custom Cabinet Frame Planning
,The custom-built
canopy should be sized to
accommodate
the hood insert sleeve. See pages
5-9 for details.
Remote Mounting
of the Control (Wired}
,The control can be remotely mounted on the well
or the countertop.
, It is recommended
that you use o professional
installer for the countertop
cutout.
, It is recommended
that the cutout in o granite
countertop
or other herd surface be made before
the countertop
is installed.
,The cutout needs to be made at least 6 inches
from the edges of the countertop.
, If mounting
in the countertop
above o drawer,
consideration
must be given to the depth of the
control mounting assembly.
,A 30 ft. wire cord is provided. Careful consideration
must be given to the location of the remotely
mounted control.
, It is recommended
that the 4-wire cord be routed
through
1" conduit between the insert sleeve end
the remote mounting
location.
POWER SUPPLY
IMPORTANT -(Please read carefully)
,&WARNING:
FOR PERSONAL SAFETY,THIS APPLIANCE MUST BE
PROPERLY GROUNDED.
Remove house fuse or open circuit breaker before
beginning
installation.
Do not use on extension
cord or adopter
plug with
this appliance.
Follow National electrical
codes or
prevailing
local codes and ordinances.
Electrical
Supply
This vent hood must be supplied with 120V, 60Hz,
end connected
to on individual, properly grounded
brunch circuit, end protected
by u 15 or 20 amp
circuit breaker or time delay fuse.
, Wiring must be 2 wire with ground.
, For supply connection,
use wires suitable for at
least 75°C (167°F).
, If the electrical supply does not meet the above
requirements,
cell e licensed electrician
before
proceeding.
, Route house wiring as close to the installation
locution us possible, in the ceiling or beck well.
, Connect the hood wiring to the house wiring in
accordance
with local codes.
, House wiring must extend to 45" minimum
from
bottom of cabinet in order to make connection
to
hood wiring.
Grounding
Instructions
The grounding
conductor
must be connected
to o
grounded
metal, permanent
wiring system, or an
equipment-grounding
terminal
or lead on the hood.
A WARNING: The
i mproper
connection
of the equipment-grounding
conductor
can result
in e risk of electric shock. Check with e qualified
electrician
or service representative
if you ere in
doubt whether the appliance
is properly grounded.