ADVANCE PLANNING

Duct Install Planning
• This hood may be vented vertically through upper cabinets,
soffit or ceiling. A duct transition piece is supplied for vertical
through the rear wall.
• Use metal ductwork only.
1. Minimize the duct run length and number of transitions
and elbows.
2. Maintain a constant duct size.
3. Seal all joints with duct tape to prevent any leaks.
• Use the shortest and straightest duct route possible.
opening. Order the wall or roof cap and any transition
needed in advance.
• When applicable, install any makeup (replacement) air
system in accordance with local building code requirements.
Visit GEAppliances.com for available makeup air solutions.
Wall Framing for Adequate Support
• This vent hood is heavy. Adequate structural support must
be provided. The hood must be secured to vertical studs in
the wall. See page 14.
• We strongly recommend that the vent hood with duct cover
be on site before final framing and wall finishing. This will
also help to accurately locate the ductwork and electrical
service.
49-80520-7
Installation Instructions
DECORATIVE DUCT COVERS
A decorative duct cover is available to fit both model widths.
The duct cover conceals the ductwork running from the top of
the hood to the ceiling or soffit. The duct cover will fit 8 ft. to 10
ft. ceiling heights. See page 12 for details.

POWER SUPPLY

IMPORTANT - (Please read carefully)
WARNING:
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY
GROUNDED.
Remove house fuse or open circuit breaker before beginning
installation.
appliance. Follow National electrical codes or prevailing local
codes and ordinances.
Electrical supply
This vent hood must be supplied with 120V, 60 Hz, and
connected to an individual, properly grounded branch circuit,
and protected by a 15 or 20 amp circuit breaker or time delay
fuse.
• Wiring must be 2 wire with ground.
• If the electrical supply does not meet the above
requirements, call a licensed electrician before proceeding.
• Route house wiring as close to the installation location as
possible in the ceiling, soffit or wall. See page 13 for details.
• Connect the wiring to the house wiring in accordance with
local codes.

Grounding instructions

The grounding conductor must be connected to a ground
metal, permanent wiring system, or an equipment-grounding
terminal or lead on the hood.
WARNING:
The improper connection of the
equipment-grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative if you are
in doubt whether the appliance is properly grounded..
9