INSTALLATION

When Installing this product...
1. Read these instructions carefully. Failure to follow
them could damage the product or cause a hazardous
condition.
2. Check ratings given in these instructions and on the
product to make sure the product is suitable for your
application.
3. Make sure the installer is a trained, experienced service
technician.
4. Use these instructions to check out product operation
after installation.
CAUTION
Equipment Damage Hazard.
Excessive pressure or temperature can damage
the device.
Make sure water temperature and pressure are below
maximum ratings specified.
CAUTION
Equipment Damage Hazard.
Excessive heat can damage internal parts.
Before sweat soldering, separate the tailpieces and
nuts from the inlet/outlet adapter.
F74C REVERSE RINSING FILTER; MV876 AUTOMATIC-BACKWASH CONTROLS
F74C Installation.
When installing an F74C, use the following procedure:
1. Shut off water supply by closing the water supply valve.
2. Install inlet/outlet adapter so that filter is vertical.
3. Install the F74C in the water line with the arrow pointing
IMPORTANT
4. Open a downstream tap.
5. Slowly open the water supply valve.
6. Once the F74C sump fills with water, close the
MV876 Installation
1. Open the backwash outlet ball valve.
2. Remove the backwash outlet handle.
3. Install the MV876. See Fig. 9 and 10.
NOTE: When you rotate the MV876 on installation, it closes
4. Connect the MV876 to a 24 Vac power supply.
5. Open a downstream tap.
6. Slowly open the water supply valve.
7. Once the F74C sump fills with water, close the
8. Program the desired backwash interval by pushing the
Fig. 9. Installing the MV876.
5
in the direction of water flow.
When using an MV876, stop here and install the
MV876.
downstream tap and fully open the water supply valve.
the backwash outlet ball valve.
See fig. 14.
downstream tap and fully open the water supply valve.
program button until the desired interval number
appears in the display.
M16481