MV876 Automatic-Backwash Controls
F74C

APPLICATION

'The F74C Reverse Rinsing Water Filters, used at
point-of-entry (POE) to remove sediment and debris from
residential or commercial water systems, ensure a continuous
supply of filtered water. The fine filter prevents the ingress of
foreign bodies, such as rust particles and grains of sand. Both
horizontal and vertical installations are possible. The flow,
filtering capacity and ease of cleaning make the F74C the
ideal filter for the most demanding applications. Both
horizontal and vertical installations are possible.
The MV876 Automatic-Backwash Control is available as an
accessory. This control is fitted to the drain valve and is
programmed by the user to automatically perform the
backwash function according to the desired interval.
® U.S. Registered Trademark
Copyright © 2001 Honeywell • All Rights Reserved
F74C Reverse Rinsing Filter;

FEATURES

F74C
• Built-in backwash impeller provides efficient cleaning
• Robust backwash mechanism.
• No shut-off or disassembly is required for cleaning.
• During backwash, the F74C continues to supply
MV876B1018
(Bayonet fitting
for F74C)
• Memory ring indicates when the next manual
• Bayonet connection enables simple retrofitting of
• Can be installed on vertical or horizontal piping.
MV876B
• Bayonet fitting simplifies upgrade to automatic
• 16 field-selectable backwash intervals (from every
• Connections for external control on the MV876 provide
• MV876 can be manually activated to initiate backwash.
• Battery (AA) backup to insure completion of backwash
Application ........................................................................
Features ...........................................................................
Specifications ...................................................................
Ordering Information ........................................................
Planning the Installation ...................................................
Installation ........................................................................
Wiring ...............................................................................
Operation ..........................................................................
with supply pressures as low as 22 psi.
filtered water without interruption through a secondary
screen.
backwash is due.
reverse rinse actuator.
backwash.
four minutes to once every three months) eliminate
need for external timer.
for use in automated systems and differential pressure
control.
cycle in spite of power loss.
Braukmann
PRODUCT DATA
Contents
1
1
2
2
4
5
7
8
62- 3061

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell Braukmann F74C

  • Page 1: Table Of Contents

    • MV876 can be manually activated to initiate backwash. horizontal and vertical installations are possible. The flow, filtering capacity and ease of cleaning make the F74C the • Battery (AA) backup to insure completion of backwash ideal filter for the most demanding applications. Both cycle in spite of power loss.
  • Page 2: Specifications

    Honeywell, 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386 (800) 328-5111 In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
  • Page 3 CLEAN SCREEN. F74C1023 M17656 TBD Opaque sump cover for F74C 3/4 in. and 1 in. Fig. 2. F74C Pressure drop vs. flow. U76S5015 3/4 in. sweat tailpiece. U76S5023 1 in. sweat tailpiece. Connections: Union on inlet and outlet: External NPT U76T1014 3/4 in.
  • Page 4: Planning The Installation

    F74C REVERSE RINSING FILTER; MV876 AUTOMATIC-BACKWASH CONTROLS PLANNING THE INSTALLATION The F74C should be sized based on the required flow rate and the resulting pressure drop across the filter. As a guideline for most applications, the F74C should be sized for a pressure drop between 3 psi and 7 psi.
  • Page 5: Installation

    2. Install inlet/outlet adapter so that filter is vertical. 1. Read these instructions carefully. Failure to follow 3. Install the F74C in the water line with the arrow pointing them could damage the product or cause a hazardous in the direction of water flow.
  • Page 6 Fig. 10. Final position of MV876 and F74C. NOTE: As the F74C operates, screens become plugged. Backwash the F74C when the pressure gauge measures about five psi To avoid unnecessary battery drainage, connect lower than when first installed. However, each installation is the MV876 to power as soon as possible after different.
  • Page 7: Wiring

    F74C once. MV876 (HOT) M17353 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. M16484 Fig. 12. Installing batteries in the MV876. Fig. 14. Wiring diagram for F74C with MV876. M17351 Fig. 13. Replacing the MV876 fuse. 62-3061...
  • Page 8: Operation

    All F74C applications are different and require backwashing at different intervals. Backwash intervals depend directly on: The F74C Water Filter removes sediment and debris from the water using an upper and lower screen. During normal — The level and type of sediment in the local water operation, no water passes through the upper screen.
  • Page 9 F74C REVERSE RINSING FILTER; MV876 AUTOMATIC-BACKWASH CONTROLS a. F74C DURING NORMAL FLOW b. F74C DURING BACKWASH CYCLE SCREEN BACKWASH IMPELLER ENLARGED ENLARGED CROSS SECTION CROSS SECTION DEBRIS AND SEDIMENT M17710 Fig. 15. Water flow through the F74C. 62-3061...
  • Page 10: F74C Replacement Parts List (See Fig. 16)

    Replacement sump assembly for Includes the sump assembly complete (ball valve, plastic F74C air gap adaptor), sump O-ring (mounted between the filter housing and the sump). M18212 Fig. 16. F74C Exploded View. parts are keyed to F74C Replacement parts List. 62-3061...
  • Page 11 62-3061...
  • Page 12 Home and Building Control Home and Building Control Honeywell Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario M1V 4Z9 Printed in U.S.A. on recycled 62-3061 G.R. 3-01 www.honeywell.com paper containing at least 10%...

This manual is also suitable for:

Braukmann mv876

Table of Contents