Page 1
Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) ISCO YSTEMS UBLICATION ISTORY 170 W ASMAN , CA, 95134 A.16 9, 2012 CTOBER CISCO...
Intel® E5-2600 series product family CPUs that deliver significant performance and efficiency gains. In addition, the UCS C220 M3 server provides 16 DIMM slots, up to 8 drives and 2 x 1 GbE LAN-on-motheroard (LOM) ports delivering outstanding levels of density and performance in a compact package.
USB, one VGA, and one serial connector) Temperature status LED Drives (up to eight hot-swappable 2-5-inch drives) For more information about the KVM cable connection, see KVM CABLE, page Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Slot 1: Standard-profile PCIe slot on riser: USB ports (full-height, half-length, x24 connector, x16 lane width) VGA video connector Rear Identification button/LED Serial port (RJ-45 connector) Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Supports all display resolutions up to 1920 x 1200 x 16 bpp resolution at ■ 60 Hz 24-bit color depth for all resolutions less than 1600x1200 ■ Up to 256 MB video memory ■ Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Page 7
A front panel controller provides status indications and control buttons Power subsystem Up to two 450 W 650 W power supplies. One is mandatory; one more can be added for 1 + 1 redundancy. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Page 8
Depending on your CIMC settings, the CIMC can be accessed through the 1-Gb Ethernet dedicated management port, the 1-Gb Ethernet LOM ports, or a Cisco P81E or Cisco 1225 virtual interface card (VIC). Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Table 2 PID of the C220 M3 High-Density SFF Rack Base Server Product ID (PID) Description UCSC-C220-M3S UCS C220 M3 SFF, no CPU, memory, HDD, SDD, power supply, SD card, or PCIe cards, with 1 rail kit The Cisco C220 M3 server: Includes one tool-less rail kit ■...
1. If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU, the DIMMs will be clocked at the lowest common denominator of CPU clock and DIMM clock. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Page 12
Table 3 on page 11). If you select DIMMs whose speeds are lower or higher than that shown in the tables, suboptimal performance will result. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Memory is organized with four memory channels per CPU, with up to two DIMMs per channel, ■ as shown in Figure Figure 4 C220 M3 SFF Memory Organization Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Page 14
8GB DDR3-1333-MHz RDIMM/PC3-10600/dual rank/x4/1.35v 1.35 V UCS-MR-1X041RY-A 4GB DDR3-1600-MHz RDIMM/PC3-12800/single rank/x4/1.35v 1.35 V UCS-MR-1X041RX-A 4GB DDR3-1333-MHz RDIMM/PC3-10600/single rank/x4/1.35v 1.35 V Memory Mirroring Option N01-MMIRROR Memory mirroring option Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Page 15
(3) 2-CPU configuration without memory mirroring: Select from 1 to 8 DIMMs per CPU. Refer to Memory Population Rules, page 50, for more ■ detailed information. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Page 16
Select the memory mirroring option (N01-MMIRROR) as shown in Table 4 on page ■ NOTE: System performance is optimized when the DIMM type and quantity are equal for both CPUs. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Page 17
1600-MHz speeds, provided: — The DIMMs are 1600-MHz devices — The CPUs chosen support 1600-MHz operation. For more information regarding memory, see CPUs and DIMMs, page Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
This option supports RAID 0, 1, 10, and 5, and operates at 3 Gb/s. Operating systems supported are Windows and Linux only (no VMware support). Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Page 19
Factory-configured RAID options available: RAID 0, 1, 10, 5, and 6 (see the ■ RAID PIDs section in this table) Super Capacitor Option UCS-RAID-CV-SC= LSI CacheVault Power Module for SAS 9266CV Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Page 20
NOTE: Although RAID levels 50 and 60 are not orderable from the factory, they are supported for selected controllers as shown in Table 5 NOTE: No RAID option can be chosen if you have no drives Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Page 21
■ cards, only the full-height PCIe card slot will be available for adding an optional PCIe card. Note that only a single Cisco VIC card (either the full-height Cisco UCS P81E or the ■ half-height Cisco VIC 1225 PCIe card) is supported and it must be installed in the full-height PCIe slot (slot 1) on riser 1.
NOTE: No RAID option can be chosen if you have no drives NOTE: No virtual drive groupings are allowed if you mix HDDs and SSDs. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Page 23
Otherwise, select up to eight SAS/SATA drives listed in Table 8. You can mix SAS and SATA ■ drives. Caveats You can mix SATA and SAS drives. ■ Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA Half N2XX-AQPCI03 Qlogic QLE2462 Dual Port 4Gb Fibre Channel HBA Half N2XX-AQPCI05 Qlogic QLE2562 Dual Port 8Gb Fibre Channel HBA Half Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Page 25
VIC 1225 PCIe card) is supported and it must be installed in slot 1 (the full height slot). All PCIe cards will fit in either slot, except the Cisco UCS P81E Virtual Interface Card (VIC), ■ which must be installed in the full-height slot (slot 1).
— UCS-PCIE-BSFP (Broadcom 57712) — N2XX-AEPCI01 (Emulex OCe10102-F) — N2XX-AIPCI01 (Intel Dual Port Ethernet X520) — UCSC-PCIE-CSC-02 (Cisco VIC 1225 Dual Port 10Gb SFP+ CNA) Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Page 27
PCIe cards, as they do not come by default with any optical modules: — N2XX-AEPCI05 (Emulex LPe 12002, 8Gb dual-port Fibre Channel HBA) Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Page 28
CONFIGURING the SERVER Figure 5 Network Card Connections Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
PID Description UCSC-PSU-450W 450 W power supply UCSC-PSU-650W 650 W power supply NOTE: In a two power supply server, both power supplies must be identical. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Plug: EL 701 EL312MoldedTwistlock (IEC60320/C13) (NEMA L6-20) CAB-C13-CBN CABASY,WIRE,JUMPER CORD, 27" L, C13/C14, 10A/250V CAB-C13-C14-2M CABASY,WIRE,JUMPER CORD, PWR, 2 Meter, C13/C14,10A/250V CAB-C13-C14-AC CORD,PWR,JMP,IEC60320/C14,IEC6 0320/C13, 3.0M Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Page 31
Connector: EL 701 SFS-250V-10A-IS Power Cord, SFS, 250V, 10A, Israel Cordset rating 10A, 250V/500V MAX (2500 mm) Connector: EL 701B Plug: (IEC60320/C13) EL 212 (SI-32) Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Page 32
(EN 60320/C15) (BS 1363A) 13 AMP fuse CAB-9K12A-NA Power Cord, 125VAC 13A NEMA 5-15 Plug, North America CAB-JPN-3PIN Power Cord 3PIN, Japan Image not available Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
PID Description UCSC-CMA1 Cable Management Arm for C220 rack servers For more information about the cable management arm, see the Cisco UCS C220 M3 Installation and Service Guide at this URL: http://www.cisco.com/en/US/docs/unified_computing/ucs/c/hw/C220/install/C220.pdf Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
The TPM ordering information is listed in Table Table 15 Trusted Platform Module Product ID (PID) PID Description UCSX-TPM1-001 Trusted Platform Module Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
STEP 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL) You can order one optional 16 GB Cisco Flexible Flash secure digital (SD) card. This SD card contains preloaded software for simplified server operation. The ordering information is listed Table...
PID Description UCS-USBFLSH-S-4GB 4GB Flash USB Drive (shorter length) for all servers except C260 Figure 6 on page 47 for the location of the USB connector. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
VMWare Server VMW-VS5-STD-1A VMware vSphere 5 Standard for 1 Processor, 1 Year, Support Required VMW-VS5-STD-2A VMware vSphere 5 Standard for 1 Processor, 2 Year, Support Required Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Page 38
VMware vSphere 5 Enterprise Plus for 1 Processor, 4 Year Support Required VMW-VS5-ENTP-5A VMware vSphere 5 Enterprise Plus for 1 Processor, 5 Year Support Required Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Windows Svr 2008 R2 ST (1-4CPU, 5CAL), Media MSWS-08R2-ENHV-RM Windows Svr 2008 R2 EN (1-8CPU, 25CAL), Media MSWS-08R2-DCHV-RM Windows Svr 2008 R2 DC (1-8CPU, 25CAL), Media Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
UC Support 8X5X4 CON-UCS3-C220-M3-W UC Support 24x7x4 CON-UCS4-C220-M3-W UC Support 24x7x2 CON-UCS5-C220-M3-W UC Support 8X5XNBD CON-UCS6-C220-M3-W UC Support 8X5X4 CON-UCS7-C220-M3-W UC Support 24x7x4 CON-UCS8-C220-M3-W UC Support 24x7x2 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Page 42
With the Cisco Unified Computing Drive Retention (UCDR) Service, you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive. In exchange for a Cisco replacement drive, you provide a signed Certificate of Destruction (CoD) confirming that the drive has been removed from the system listed, is no longer in service, and has been destroyed.
Page 43
If a problem arises that threatens business continuity, the TAM provides crisis management leadership, and your IT staff receives expedited access to Cisco's Technical Assistance Center (TAC). Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Page 44
For more service and support information, see this URL: http://www.cisco.com/en/US/services/ps2961/ps10312/ps10321/Cisco_UC_Warranty_Support_DS.pdf For a complete listing of available services for Cisco Unified Computing System, see this URL: http://www.cisco.com/en/US/products/ps10312/serv_group_home.html Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
OPTIONAL STEP - ORDER RACK(s) The optional R42610 rack is available from Cisco for the C-Series servers, including the C220 M3 SFF server. This rack is a standard 19-inch rack and can be ordered with a variety of options, as...
M3 server. This PDU is available in a zero rack unit (RU) style (see Table 24). Table 25 PDU Options Product ID (PID) PID Description RP208-30-2P-U-2 Zero RU PDU For more information about the PDU, see PDUs, page Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
2 SCU upgrade ROM header (RAID key). Cisco Flexible Flash SD socket SD1 on PCIe riser 2 DIMM slots on motherboard (16) Internal USB port Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
H) are associated with CPU2. The bank 1 (blue) DIMM slots are always located farther away from a CPU than the corresponding bank 2 (black) slots. Bank 1 slots (blue) are populated before bank 2 slots (black). Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Page 49
SUPPLEMENTAL MATERIAL Figure 7 Physical Layout of CPU DIMM Channels and Banks CPU1 CPU2 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Notes . . . 1. Only 1333 and 1600 MHz DIMMs are currently available for the C220 M3 server. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
NOTE: If you do not select a mezzanine card, a plug-in PCIe RAID card, or one of the embedded RAID upgrade options, you will have an embedded SATA-only RAID controller that supports up to four SATA-only drives (RAID 0, 1, 10) Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
(954 kg) (954 kg) Dynamic load capacity Not applicable Not applicable NOTE: The AC input connector is an IEC 320 C-14 15 A/250 VAC power inlet. Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Page 56
SUPPLEMENTAL MATERIAL Figure 8 Cisco R42610 Rack Front view - door closed Front view - door open Front view - door removed Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
With a Cisco RP Series PDU in the rack, you can replace up to two dozen input power cords with just one. The fixed input cord connects to the power source from overhead or under-floor distribution. Your IT equipment is then powered by PDU outlets in the rack using short, easy-to-manage power cords.
Figure 10 KVM Cable Connector (to server front panel) VGA connector (for a monitor) DB-9 serial connector Two-port USB connector (for a mouse and keyboard) Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Maximum AC inrush current 11 A Maximum output power for each 450 W power supply Power supply output voltage Main power: 12 VDC Standby power: 12 VDC Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Page 61
NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet. For configuration-specific power specifications, use the Cisco UCS Power Calculator at this URL: https://express.salire.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
0 to 12,192 m (0 to 40,000 ft.) Sound Power level, Measure A-weighted per ISO7779 LWAd (Bels)Operation at 73°F (23°C) Sound Pressure level, Measure A-weighted per ISO7779 LpAm (dBA)Operation at 73°F (23°C) Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CISPR22 Class A EN55022 Class A ICES003 Class A VCCI Class A EN61000-3-2 EN61000-3-3 KN22 Class A CNS13438 Class A EMC - Immunity EN55024 CISPR24 EN300386 KN24 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Page 64
TECHNICAL SPECIFICATIONS Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)