Cisco UCS C22 M3 User Manual

Cisco UCS C22 M3 User Manual

High-density rack-mount server (small form factor hard disk drive model)
Hide thumbs Also See for UCS C22 M3:

Advertisement

Quick Links

Cisco UCS C22 M3
High-Density Rack-Mount
Server
(Small Form Factor Hard
Disk Drive Model)
C
S
ISCO
YSTEMS
170 W
T
D
.
EST
ASMAN
R
S
J
, CA, 95134
AN
OSE
.
.
WWW
CISCO
COM
P
H
UBLICATION
ISTORY
R
A.1
N
2, 2012
EV
OVEMBER

Advertisement

Table of Contents
loading

Summary of Contents for Cisco UCS C22 M3

  • Page 1 Cisco UCS C22 M3 High-Density Rack-Mount Server (Small Form Factor Hard Disk Drive Model) ISCO YSTEMS UBLICATION ISTORY 170 W ASMAN , CA, 95134 2, 2012 OVEMBER CISCO...
  • Page 2: Table Of Contents

    Compliance Requirements ..........61 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 3: Overview

    Building on the success of the Cisco UCS C-Series Servers, the Cisco UCS C22 M3 server and the Cisco 1225 VIC further extend the capabilities of the Cisco UCS portfolio in a 1RU form factor with the addition of the Intel®...
  • Page 4: Detailed Views

    DETAILED VIEWS DETAILED VIEWS Chassis Front View Figure 2 shows the Cisco UCS C22 M3 High-Density SFF Rack Server. Figure 2 Chassis Front View 5 6 7 HDD01 HDD02 HDD03 HDD04 HDD04 HDD04 HDD05 HDD05 HDD05 HDD06 HDD07 HDD08 Power button/power status LED...
  • Page 5: Chassis Rear View

    Slot 1: Standard-profile PCIe slot on riser 1 10/100/1000 Base-T Ethernet dedicated (x16 PCIe Gen 3 slot, x16 extended management port connector (Cisco CNIC), half-length, full-height) Dual 1-Gb Base-T Ethernet ports (two) Rear Identification button/LED USB 2.0 ports (four) Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 6: Base Server Standard Capabilities And Features

    Expansion slots Two riser cards with one PCIe card slot in each riser Riser 1 (controlled by CPU 1) ■ • One x16 PCIe Gen 3 slot, x16 extended connector (Cisco CNIC), half-length, full-height, with NCSI and Cisco CNIC support. The Cisco 1225 virtual interface card requires an NCSI slot.
  • Page 7 Cisco 1225 virtual interface card. Notes . . . 1. NCSI = network communications services interface protocol. The slot stays active when the server is in standby power state. 2. CNIC = Cisco network interface card. Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 8: Configuring The Server

    CONFIGURING the SERVER CONFIGURING the SERVER Follow these steps to configure the Cisco UCS C22 M3 High-Density SFF Rack Server: STEP 1 VERIFY SERVER SKU, page 9 ■ STEP 2 SELECT CPU(s), page 10 ■ STEP 3 SELECT MEMORY, page 12 ■...
  • Page 9: Step 1 Verify Server Sku

    Table 2 PID of the C22 M3 High-Density SFF Rack Base Server Product ID (PID) Description UCSC-C22-M3S UCS C22 M3 SFF with rail kit, without PSU, CPU, memory, HDD, or PCIe cards The Cisco C22 M3 server: Includes a rail kit ■...
  • Page 10: Step 2 Select Cpu(S)

    Caveats You can select either one processor or two identical CPUs. ■ If you select one CPU, only one PCIe slot (the full-height slot on riser 1) is available for use. ■ Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 11 For optimal performance, select DIMMs with the highest clock speed for a given processor ■ (see Table 3 on page 10). If you select DIMMs whose speeds are lower or higher than that shown in the tables, suboptimal performance will result. Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 12: Step 3 Select Memory

    Registered ECC DDR3 DIMMS (RDIMMS) Memory is organized with three memory channels per CPU, with up to two DIMMs per ■ channel, as shown in Figure Figure 4 C22 M3 SFF Memory Organization Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 13 DIMM Placement in Channels DIMMs (Channel C is not used with memory mirroring) 1 DIMM in Channel A, 1 DIMM in Channel B 2 DIMMs in Channel A, 2 DIMMs in Channel B Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 14 (service profile) to run in Performance Mode. This forces the DIMMs to operate at 1.5 V and yields 1600-MHz speeds, provided: — The DIMMs are 1600-MHz devices — The CPUs chosen support 1600-MHz operation. For more information regarding memory, see CPUs and DIMMs, page Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 15: Step 4 Select Raid Configuration

    LSI MegaRAID 9220-8i — LSI MegaRAID 9220-4i Cisco can provide factory-configured RAID systems depending on the RAID controller card chosen and the number of drives ordered. Factory-configured RAID options are listed in Table NOTE: Factory-configured RAID is not available if you choose software RAID (in this case, you must configure RAID yourself using separate software).
  • Page 16 No data cache backup. There is no direct attached buffer memory. The ■ controller utilizes system RAM for buffer cache memory. RAID levels supported: RAID 0, 1, 10 (see the RAID Configuration Options ■ section later in this table) Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 17 Table 8 on page 21 — If you choose a plug-in RAID controller from Table 5 on page 15, you will not be able to select any optional PCIe card from Table 8 on page Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 18 2-CPU configuration, only the full-height PCIe card slot will be available for an additional optional PCIe card. Note that only a single Cisco 1225 Virtual Interface Card (VIC) card is supported and it must ■ be installed in the full-length, full-height PCIe slot (slot 1) on riser 1, which is the only slot that supports NCSI.
  • Page 19: Step 5 Select Hard Disk Drives (Hdds)

    NOTE: No factory-configured RAID option can be chosen (a factory RAID volume is not available) if: there are no drives, or ■ SAS and SATA drives are mixed, or ■ different capacity drives are mixed ■ Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 20 If you select one or more HDDs, you must select either a PCIe RAID controller from Table 6 ■ on page 16 or a software RAID option from Table 5 on page Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 21: Step 6 Select Pcie Option Card(S)

    Qlogic QLE2562, 8Gb dual port Fibre Channel HBA Half Notes . . . 1. The “QSFP” in UCSC-PCIE-QSFP stands for QLogic SFP (QSFP is not to be confused with 40 GbE QSFP) Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 22 All PCIe cards will fit in either riser 1 or riser 2, except the VIC card, which must be installed ■ in the full-height slot of riser 1. The Cisco 1225 VIC card must be plugged into slot 1, which supports NCSI.
  • Page 23: Step 7 Order Optional Network Card Accessories

    Caveats The twinax cables listed in Table 9 can be ordered only for the following PCIe cards: — UCSC-PCIE-CSC-02 (Cisco VIC 1225 Dual Port 10Gb SFP+ CNA) — UCS-PCIE-BSFP (Broadcom 57712) — N2XX-AEPCI01 (Emulex OCe10102-F) —...
  • Page 24 Table 10 should be ordered only for the following PCIe cards, as they do not come by default with any optical modules: — UCSC-PCIE-CSC-02 (Cisco VIC 1225 Dual Port 10Gb SFP+ CNA) — UCSC-PCIE-BSFP (Broadcom 57712) — N2XX-ABPCI02 (Broadcom 57711) —...
  • Page 25 CONFIGURING the SERVER Figure 5 Network Card Connections Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 26: Step 8 Select Ac Power Cord(S)

    Cordset rating 13A, 250V (6.6 feet) (79±2m) Connector: Plug: EL 701 EL312MoldedTwistlock (IEC60320/C13) (NEMA L6-20) CAB-C13-CBN CABASY,WIRE,JUMPER CORD, 27" L, C13/C14, 10A/250V CAB-C13-C14-2M CABASY,WIRE,JUMPER CORD,PWR, 2 Meter, C13/C14, 10A/250V CAB-C13-C14-AC CORD,PWR,JMP,IEC60320/C14,IEC6 0320/C13, 3.0M Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 27 Cordset rating 16A, 250V Plug: (2500mm) EL 208 Connector: EL 701 SFS-250V-10A-IS Power Cord, SFS, 250V, 10A, Israel Cordset rating 10A, 250V/500V MAX (2500 mm) Connector: EL 701B Plug: (IEC60320/C13) EL 212 (SI-32) Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 28 EL 701C EL 210 (EN 60320/C15) (BS 1363A) 13 AMP fuse CAB-9K12A-NA Power Cord, 125VAC 13A NEMA Image not available 5-15 Plug, North America CAB-JPN-3PIN Power Cord 3PIN, Japan Image not available Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 29: Step 9 Order Power Supply

    650 W power supply. The UCS Power Calculator can be found at the following link: https://express.salire.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx Table 12 Power Supply PIDs Product ID (PID) PID Description UCSC-PSU-450W 450 W power supply UCSC-PSU-650W 650 W power supply Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 30: Step 10 Order Optional Reversible Cable Management Arm

    NOTE: If you order and install a cable management arm, you will need the longest power cable available. For more information about the cable management arm, see the Cisco UCS C22 M3 Installation and Service Guide at this URL: http://www.cisco.com/en/US/docs/unified_computing/ucs/c/hw/C22/install/C22.pdf...
  • Page 31: Step 11 Order A Trusted Platform Module

    The TPM ordering information is listed in Table Table 14 Trusted Platform Module Product ID (PID) PID Description UCSX-TPM1-001 Trusted Platform Module Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 32: Step 12 Order Optional Usb 2.0 Drives

    16 GB Flash USB Drive for C22/C24, preloaded with UCS SCU/HUU bootable images and driver ISO file Figure 6 on page 43 for the location of the internal 8 GB USB connector. Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 33: Step 13 Select Operating System

    Windows Svr 2008 ST media R2 ST (1-4CPU, 5CAL) MSWS-08R2-ENHV Windows Svr 2008 EN media R2 EN (1-8CPU, 25CAL) MSWS-08R2-DCHV2S Windows Svr 2008 R2-2 CPU-Data Center MSWS-08R2-DCHV4S Windows Svr 2008 R2-4 CPU-Data Center Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 34 VMware vSphere 5 Enterprise Plus for 1 Processor, 3 Year, Support Rqd VMW-VS5-ENTP-4A VMware vSphere 5 Enterprise Plus for 1 Processor, 4 Year Support VMW-VS5-ENTP-5A VMware vSphere 5 Enterprise Plus for 1 Processor, 5 Year, Support Rqd Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 35: Step 14 Select Operating System Media Kit

    SLES 11 media only (multilingual) MSWS-08R2-STHV-RM Windows Svr 2008 R2 ST (1-4CPU, 5CAL), Media MSWS-08R2-ENHV-RM Windows Svr 2008 R2 EN (1-8CPU, 25CAL), Media MSWS-08R2-DCHV-RM Windows Svr 2008 R2 DC (1-8CPU, 25CAL), Media Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 36: Step 15 Select Optional Value-Added Software

    VMware vCenter 5 Standard for 1 Processor, 3 Year, Support Rqd VMW-VC5-STD-4A VMware vCenter 5 Standard for 1 Processor, 4 Year, Support Rqd VMW-VC5-STD-5A VMware vCenter 5 Standard for 1 Processor, 5 Year, Support Rqd Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 37: Step 16 Select Service And Support Level

    Warranty Plus provides remote access any time to Cisco support professionals who can determine if a return materials authorization (RMA) is required. See...
  • Page 38 CONFIGURING the SERVER world. As a part of this service, Cisco will assist in issues involving third-party software that have been certified for use on the Cisco Unified Computing System For Cisco UCS servers under Cisco Unified Computing System Manager (UCSM), you get Smart Call Home, which provides proactive, embedded diagnostics and real-time alerts.
  • Page 39 IT staff receives expedited access to Cisco's Technical Assistance Center (TAC). Mission Critical Support Service is a layered service available for all Cisco data center products already support by a UCS Support Service or SMARTnet service contract. For further information...
  • Page 40 Cisco account Manager. For more service and support information, see this URL: http://www.cisco.com/en/US/services/ps2961/ps10312/ps10321/Cisco_UC_Warranty_Support_DS.pdf For a complete listing of available services for Cisco Unified Computing System, see this URL: http://www.cisco.com/en/US/products/ps10312/serv_group_home.html Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 41: Optional Step - Order Rack(S)

    OPTIONAL STEP - ORDER RACK(s) The optional R42610 rack is available from Cisco for the C-Series servers, including the C22 M3 SFF server. This rack is a standard 19-inch rack and can be ordered with a variety of options, as...
  • Page 42: Optional Step - Order Pdu

    OPTIONAL STEP - ORDER PDU OPTIONAL STEP - ORDER PDU An optional power distribution unit (PDU) is available from Cisco for the C-Series rack servers, including theC22 M3 server. This PDU is available in a zero rack unit (RU) style (see Table 22).
  • Page 43: Supplemental Material

    Front panel operations board PCIe riser 2 (PCIe slot 2) Drive backplane Trusted platform module socket on motherboard (not visible under PCIe riser 2) Cooling fans (five) Power supply (accessed through rear panel) Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 44: Cpus And Dimms

    (channels A, B, and C) are associated with CPU 1, while the DIMM slots on the bottom (channels D, E, and F) are associated with CPU 2. Bank 0 slots (blue) are populated before Bank 1 slots (black). Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 45 SUPPLEMENTAL MATERIAL Figure 7 Physical Layout of CPU DIMM Channels and Banks CPU1 CPU2 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 46: Memory Population Rules

    8 GB DIMMs and black slots with 4 GB DIMMs and total memory size should be 12 GB across all 3 channels for both CPUs. — When mixing DIMMs, all the DIMMs in the server must be the same speed. Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 47: Recommended Memory Population

    2 DPC while maintaining the maximum memory speed at 1600 MHz. • 12 x 8GB gives the peak performance for this configuration and is recommended if there is no plan of increasing the total memory in the future. Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 48: Supported Dimm Populations

    96 GB 192 GB Notes . . . 1. UCS-MR-1X082RY-A + UCS-MR-1X041RY-A 2. UCS-MR-1X082RY-A + UCS-MR-1X041RY-A 3. UCS-MR-1X162RY-A + UCS-MR-1X041RY-A 4. UCS-MR-1X162RY-A + UCS-MR-1X041RY-A 5. UCS-MR-1X082RY-A + UCS-MR-1X162RY-A 6. UCS-MR-1X082RY-A + UCS-MR-1X162RY-A Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 49: Low-Voltage Dimm Considerations

    That is, the server cannot operate in Power Saving Mode unless all DIMMs are low-voltage DIMMs. CPUs that have a maximum memory frequency less than 1333 MHz support low-voltage ■ DIMMs operating in Power Saving Mode only, and do not support Performance Mode. Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 50: Racks

    SUPPLEMENTAL MATERIAL RACKS The Cisco R42610 rack (see Figure 8) is certified for Cisco UCS installation at customer sites and is suitable for the following equipment: Cisco UCS B-Series servers and fabric interconnects ■ Cisco UCS C-Series and select Nexus switches ■...
  • Page 51 SUPPLEMENTAL MATERIAL Figure 8 Cisco R42610 Rack Front view - door closed Front view - door open Front view - door removed Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 52: Pdus

    With a Cisco RP Series PDU in the rack, you can replace up to two dozen input power cords with just one. The fixed input cord connects to the power source from overhead or under-floor distribution. Your IT equipment is then powered by PDU outlets in the rack using short, easy-to-manage power cords.
  • Page 53: Motherboard Usb Port

    Motherboard USB Port SYS FAN1 CPU 1 PCIe 1 SYS FAN2 SYS FAN3 SYS FAN4 PCIe 2 CPU 2 SYS FAN5 PSU 1 Internal USB 2.0 port (on motherboard under PCIe riser 1) Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 54: Led Indicators

    CIMC and some motherboard functions) On (green) Card power is on Unit ID Unit ID not active (LED is integrated into On (blue) Unit ID is activated unit ID button) Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 55 Blinking (amber) One or more power supplies are in a critical fault state. Network Link Status Undefined On (green) Link pulses detected on any of the LOM ports, but no activity. Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 56: Rear Panel

    10/100/1000 Ethernet dedicated management link status LED Power supply AC OK LED 10/100/1000 Ethernet dedicated management link speed LED 1-Gb Ethernet link speed LED Rear Identification button/LED 1-Gb Ethernet link status LED Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 57 On (amber) Link Speed = 100 Mbps On (green) Link Speed = 1 Gbps Unit ID Unit ID not active (LED is integrated into On (blue) Unit ID is activated unit ID button) Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 58: Technical Specifications

    23.48 lbs (10.65 kg) Power Specifications The general power specifications for the C22 M3 SFF server 450 W power supply are listed in Table Table 30 UCS C22 M3 SFF 450 W Power Supply Specifications Description Specification AC input voltage...
  • Page 59: Environmental Specifications

    Power supply efficiency CSCI Platinum NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet. For configuration-specific power specifications, use the Cisco UCS Power Calculator at this URL: https://express.salire.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx Environmental Specifications The power specifications for the C22 M3 server are listed in...
  • Page 60 0 to 12,192 m (0 to 40,000 ft.) Sound Power level, Measure A-weighted per ISO7779 LWAd (Bels) Operation at 73°F (23°C) Sound Pressure level, Measure A-weighted per ISO7779 LpAm (dBA) Operation at 73°F (23°C) Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 61: Compliance Requirements

    47CFR Part 15 (CFR 47) Class A AS/NZS CISPR22 Class A CISPR22 Class A EN55022 Class A ICES003 Class A VCCI Class A EN61000-3-2 EN61000-3-3 KN22 Class A CNS13438 Class A EMC - Immunity EN55024 CISPR24 EN300386 KN24 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
  • Page 62 TECHNICAL SPECIFICATIONS Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...