What should ! do if the Service light is blinking?
The red Service light blinks when the internal diagnostics
detect a problem with TrueSTEAM Follow these steps
to try and correct the problem:
1. Press and hold the Go button to clear the fault. If TrueSTEAM can reset itself, the Service light will
stop blinking, and TrueSTEAM will operate normally. No further action is required.
2. If the fault doesn't clear, unplug the TrueSTEAM power cord and plug it back in to the electrical outlet.
3. If the fault reappears, wait 24 hours before calling a HVAC Professional Installer. TrueSTEAM may correct
itself automatically.
What if l am having a problem with TrueSTEAM?
If you have difficulty with TrueSTEAM, please try the following suggestions.
Most problems can be corrected
quickly and easily.
Problem
Symptoms
or Causes
Steps to Fix
(Performed
Only By Professional
HVAC Technician)
........................................................................................................................................................................
Low humidity
TrueSTEAM not
1. Confirm the Power light is on.
producing steam.
2. Set the humidity control and/or frost setting higher. See
"How do I use the humidity control" on page 11.
3. Check that the furnace power is on.
4. Reset your circuit breaker or check for a blown fuse.
5. If fault persists, turn the humidity control off. Unplug
TrueSTEAM, reset circuit breaker, and call a HVAC
Professional Contractor.
Rapid air changes.
1. Keep doors and windows closed.
Drafts (cold air is dry
2. Close fireplace damper when not in use.
and is an added load
3. Keep exhaust fan running time to a minimum.
for TrueSTEAM).
4. Seal around doors and windows.
5. Ask your Professional Installer about ventilation solutions
that retain indoor humidity (such as an Energy
Recovery Ventilator).
High humidity
Condensation
on walls.
1. Turn off the humidity control and/or frost setting until
condensation
has completely evaporated.
2. Once condensation
has evaporated,
readjust the humidity
setpoint and/or frost setting to a lower setting to prevent
reoccurrence
of condensation.
See "How do I use the
humidity control?" on page 11.
Heavy condensation
1. Turn the humidity control down low enough to eliminate
on windows,
condensation
caused by moisture from bathing, mopping,
cooking, etc.
2. If moisture persists, more ventilation is needed.
22
TrueSTEAM Humidification
System
69-2286EF--01