Honeywell HM700A1000 Installation Instructions Manual

Honeywell HM700A1000 Installation Instructions Manual

Electrode steam humidifier
Hide thumbs Also See for HM700A1000:

Advertisement

HM700A1000
ELECTRODE STEAM HUMIDIFIER
INTRODUCTION
The HM700 is the most advanced residential steam humidifier
available and provides steady and reliable humidification for a
home. The humidifier is designed for connection to a steam
distributor installed in a supply air duct for humidity on
demand.
IMPORTANT
Read and save these instructions. This guide should
be kept by the installer, and the Homeowner's Guide
should be left with the equipment owner.
Included in the Box
— Steam Humidifier (HM700)
— Distribution Remote Mount Kit (HM700ADISTKIT)
— HumidiPRO Humidistat (H6062A1000)
— Steam Cylinder (one HM700ACYL2 included)
— Rubber drain hose
— Installation Instructions, Homeowner's Guide and
Quick Start Guide
Part Number
Volts
110/120
HM700A1000
220/240
Table 1. Specifications.
Steam
Output
GPD
KW
Amps Phase
11
1.4
12.0
22
2.8

INSTALLATION INSTRUCTIONS

Tools Needed

— Screwdriver
— Wrench
— Pliers
— Shut-off water valve
— Water line (LDPE or Copper)

Humidifier Configuration

The HM700 is configured at the factory to operate under most
conditions without the need to change its configuration.
NOTE: Because the humidifier is factory configured for
optimal performance, Honeywell strongly
discourages changes to the jumpers or the
potentiometer; doing so will void the warranty
and could damage the humidifier. Contact
Honeywell Customer Care for further
information.
Before Installation
1. Ensure that available voltage and phase corresponds
with humidifier voltage and phase as indicated on
humidifier's specification label.
2. Ensure that the dedicated external fuse disconnect is of
sufficient size to handle the rated amps as indicated on
the specification label. Refer to local codes.
3. Ensure sufficient clearances will be available as
described in the Location section on page 5.
4. Ensure steam lines can be routed to duct distributor as
described in Steam Lines and Condensate Return
Instructions on page 8.
Max Ext
Standard
Fuse
Cylinder
1
15 A
CYL2
Net/Full
Dimensions
Weight
in inches
lbs. (kg)
(L x W x H)
15 / 20
11.5 x 6.75 x 21.5
(7.0 / 9.5)
33-00118-01

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell HM700A1000

  • Page 1: Installation Instructions

    Honeywell strongly discourages changes to the jumpers or the potentiometer; doing so will void the warranty and could damage the humidifier. Contact Honeywell Customer Care for further information. INTRODUCTION Before Installation 1. Ensure that available voltage and phase corresponds...
  • Page 2: Parts And Accessories

    CAUTION touched. Water quality Honeywell does not accept any liability for installations The Honeywell HM700 requires a cold water of humidity equipment installed by unqualified connection from your home's main water supply personnel or the use of between 30-100 PSIG.
  • Page 3: How The Humidifier Works

    HM700A1000 How the Humidifier Works The HM700 is an atmospheric steam generator that uses heat capacity. The HM700 software monitors this condition and, generated by electrical current flowing between submerged when detected, will stop operating and flash the yellow electrodes to generate steam. The HM700 is designed for on- LED in a repeating sequence of 4 flashes.
  • Page 4 HM700A1000 1 - R/HUM 2 - HUM 3 - C 4 - N/A 8 - AP 19 - Gf 20 - Rf 21 - N/A (Optional) 1/8 NPT to 1/4 compression or LDPE water line Fig. 2. Typical HM700 Installation.
  • Page 5: Mounting With Keyholes

    Consult local and national codes before final 2. Use #8 x 2 in. (5 cm) screws mounted into 2x4 studs or location and installation. Honeywell does not accept better. 2 screws are needed, one for hanging the unit responsibility for installation code violations.
  • Page 6 HM700A1000 PLUMBING USE 1/4 IN. COMPRESSION FITTING (INCLUDED) TO CONNECT WATER SUPPLY LINE TO UNIT (LDPE PLASTIC OR COPPER). 1/2 IN. (30 MM) OD FILL AND DRAIN LINES CAN ALSO BE ROUTED THROUGH OPENING IN BACK OF CABINET. ALWAYS INSTALL A WATER SHUT-OFF VALVE.
  • Page 7: Steam Distributor

    HM700A1000 Steam Distributor The HM700 requires a steam distributor installed in the The steam distributor should be installed as close as possible supply-side of ductwork. The HM700 can distribute steam into to the humidifier. Short steam distribution lines minimize a ventilation duct using the distributor shown in Table 5.
  • Page 8: Steam Lines And Condensate Return Instructions

    (3.5) (0.7) The use of steam line other than copper, stainless steel tube or Honeywell supplied steam line will void the warranty and may adversely affect the operation of the humidifier. When using copper or stainless steel tubing (other than the supplied tubing), insulation is recommended due to high temperature safety as well as reduced condensate.
  • Page 9: Steam Line Installation Examples

    HM700A1000 Steam Line Installation Examples 12 (305) 2 (51) 12 (305) MINIMUM MINIMUM RADIUS 12 (305) MINIMUM CONDENSATE RADIUS LINE 12 (305) MINIMUM BEFORE SUPPORT SUPPORT ANY BEND 12 (305) BRACKETS BRACKETS MINIMUM BEFORE ANY BEND CONDENSATE LINE OBSTRUCTION CONNECT...
  • Page 10: Installation Steps

    Fig. 15. Primary power connection. NOTES: — Honeywell requires the use of a GFI circuit on this device to protect the homeowner from electrical shock. — When installed correctly, the green wire should be removed from the drain valve. The green wire comes pre-installed from the factory to protect the homeowner in case of an improper installation or when it is not possible to retrofit a GFI circuit.
  • Page 11: External Controls

    HumidiPRO control or some other thermostat (such as the ® • Can be located either in return air duct (preferred) or in Honeywell Prestige of VisionPRO ) can be used to enable a room being humidified. fan on a call for humidity. If using another thermostat, consult •...
  • Page 12: Installation Check

    HM700A1000 START UP Installation Check Before turning on power to the HM700, inspect the installation to ensure that it was carried out correctly. Air Proving (optional) High Limit In series between On/Off terminals 1 and 2. Bend, or other (optional)
  • Page 13: Start-Up Procedure

    HM700A1000 Start Up Procedure 1. Examine the humidifier and installation for damage 7. Check and adjust the control setpoint on the control and and/or improper installation. high limit humidistat. 2. Ensure the cylinder is properly seated in the drain valve 8.
  • Page 14: Operation

    HM700A1000 OPERATION LED Status Lights the cylinder. The LED is on for information only and unless it persists for an extended period of time, it does The HM700 user interface includes 2 LEDs that provide not require any action. information about the humidifier status.
  • Page 15 HM700A1000 High Water Sensor Steam Outlet Plug Condensate Return Fill Cup Cylinder Plug High Voltage Terminal Block Cylinder Transformer Power Relay Control Board Fill Valve Control Terminal Strip On/Off/Drain Switch Drain Canal Drain Valve Fig. 20. Humidifier components. 33-00118—01...
  • Page 16 HM700A1000 Component Function Condensate Return Provides a connection to return condensate to humidifier. Control Terminal Strip Terminal strip for connecting external controls to humidifier and interfacing with other equipment. Cylinder Plug Power connectors to electrodes in cylinder. Cylinder Holds electrodes in water. Current between electrodes generates heat used to generate steam.
  • Page 17: Maintenance And Servicing

    Honeywell cylinder when the software advises that the cylinder is spent is not responsible for any damages resulting from,...
  • Page 18: Removing The Cylinder

    HM700A1000 Removing the Cylinder 3. Close supply water shut off valve. 4. Turn off power to the humidifier with the external discon- nect. WARNING 5. Remove the two screws securing the front cover. 6. Remove the cylinder plugs from the cylinder pins by Disconnect main power at the external disconnect pulling vertically.
  • Page 19: Drain Valve Cleaning

    HM700A1000 Drain Valve Cleaning Always clean the drain valve before installing a new cylinder. Scale from the spent cylinder may have fallen into the drain valve and could prevent its proper operation. To properly clean the drain valve it must be removed and disassembled.
  • Page 20: Starting After Extended Shutdown

    HM700A1000 Extended Shutdown the accumulation of algae and bacteria growing in the cylinder. The cylinder will remain empty Should it be required to disconnect power to the humidifier for until there is a call for humidity at which time the a period of extended shut-down, always drain the cylinder first.
  • Page 21: Troubleshooting Requirements

    HM700 wiring diagram is also included at the end of this should be done by qualified personnel. chapter for reference purposes. • When contacting your local representative or Honeywell for CAUTION troubleshooting assistance, please ensure the serial number has been obtained for reference purposes.
  • Page 22 HM700A1000 Table 7. General troubleshooting. (Continued) Symptom Cause Corrective Action(s) Distributor spitting out water Distributor not level Use support at end of distributor to ensure it is level. “P” Trap too close to distributor “P” Trap must be a minimum of 12 in (30 cm) below the distributor to ensure flow.
  • Page 23 Fill valve may be defective - replace if necessary Water supply too conductive a) Change the water supply b) Contact Honeywell representative for recommendation Humidifier short cycling a) Check if high limit or other On/Off control is cycling On/Off in less than 5 minutes. Check location and setting of high limit.
  • Page 24 HM700A1000 HIGH WATER POTENTIOMETER CYLINDER FILL V DRAIN V STATUS LAMPS ON/OFF/ DRAIN SWITCH 1.5 AMPS TRANSFORMER INTERNAL 240 P 240 VAC EXTERNAL 19 20 21 240 P 120 VAC NOTE: DRY POINTS FOR FURNACE FAN ENABLE. 24 V PILOT CONTROL ONLY...
  • Page 25: Year Warranty

    This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect was caused by damage which occurred while the product was in the possession of a consumer.
  • Page 26 HM700A1000 33-00118—01...
  • Page 27 HM700A1000 33-00118—01...
  • Page 28 HM700A1000 Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North ® U.S. Registered Trademark Golden Valley, MN 55422 © 2015 Honeywell International Inc. 33-00118—01 M.S. 11-15 customer.honeywell.com Printed in United States...

Table of Contents