Powering The Server On And Off; Power States; Powering On The Server; Powering On The Server Using The Ilo Mp Pc Command - HP rp4410 Service Manual

User service guide, fifth edition - hp 9000 rp4410/4440
Hide thumbs Also See for rp4410:
Table of Contents

Advertisement

2.
Connect the monitor, keyboard, and mouse cables.
a.
Connect the monitor VGA cable to the appropriate VGA port on the server.
b.
Connect the keyboard USB cable to the appropriate USB port on the server.
c.
Connect the mouse USB cable to the appropriate USB port on the server.
3.
Power on the server. The BCH Main Menu prompt displays.
The graphic console output displays on the monitor screen.

Powering the Server On and Off

This section provides information and procedures for powering on and powering off the server.

Power States

The server has three power states:
Standby power
Full power
Off
Table 3-17
lists the server power states.
Table 3-17 Power States

Power States

Standby power
Full power
Off
NOTE:
If the power restore feature is set to Always On through the iLO MP PR command,
the server automatically powers on to the full power state when the power cord is plugged in
to the server.

Powering On the Server

Power on the server to full power using the following methods if the server is in the standby
power state:
iLO MP PC command
Power button

Powering On the Server Using the iLO MP PC Command

NOTE:
If the power restore feature is set to Always On through the iLO MP PR command, the
server automatically powers on to the full power state when the power cord is plugged in to the
server.
To power on the server using the iLO MP PC command, follow these steps:
1.
Plug all power cables into the receptacles on the rear panel of the server.
2.
Initiate a console session, and access the MP Main Menu.
3.
To enable command mode, enter CM.
4.
To use the remote power control command, enter PC.
5.
To power on the server, enter ON.
6.
to confirm the action, enter YES when prompted.
Power Cable
Power Activated through the iLO MP PC
Plugged Into
Command; or Front Panel Power Button
Receptacle?
Activated?
Yes
No
Yes
Yes
No
No
Standby dc
dc Voltage
Voltage
Applied?
Applied?
Yes
No
Yes
Yes
No
No
Powering the Server On and Off
115

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rp44409000 rp4410-49000 rp4440-89000 rp44109000 rp4440

Table of Contents