Troubleshooting Procedures; General Specifications; Wattage Specifications; Exhaust Ducts - Maytag MDE/MDG21PDA Service Manual

Commercial single and stack dryers
Table of Contents

Advertisement

Troubleshooting Procedures

To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing, unless testing
requires power.

General Specifications

Capacity
6.0 Cubic Feet
Motor
Thermo-protected against overload auto-reset
Air Flow
Cubic feet per minute exhausted from dryer
Tumbler
Revolution per minute
Rotation
Drum Turning, when viewed from the front
Heat Source
• Electric
• Gas
Exhaust
Venting size
Makeup Air
Free opening
Static Pressure
Single unit exhausting, 4" round rigid

Wattage Specifications

DESCRIPTION
Gas Dryer
Electric
Heating Element
Igniter (NOTE: Ohm room temperature 180-400)

Exhaust Ducts

©2004 Maytag Appliances Company
!
WARNING
WATTS
350 Maximum without igniter
5900 (240V)/5600 208V)
5600 (240V)/5100 (208V)
600
16022904 Rev. 0
One washer load is a full dryer load
1/4 HP, 120 Volt, 60 Hz
220 CFM
52 RPM
Clockwise
• 240 volt, 5600 watts, 30 amp fuse
• Single port burner 24,000 BTU/hr.
direct ignition, automatic shut-off
4"(10.2 cm) duct, rigid aluminum
duct work. (See installation instruc-
tions that are provided with the
product for additional information.)
Requires 30 sq. in. per dryer pocket
Should not exceed 0.92" or less
than 0 water column inches