Creating Provisioning Scripts
Open Format Configuration File
Cisco Small Business IP Telephony Devices Provisioning Guide
between them. In the following example, the GPP_A parameter is set to an
empty string.
<flat-profile>
<GPP_A>
</GPP_A>
</flat-profile>
Attributes
•
Element attributes are allowed. Their value must be enclosed by double
quotes. All such attributes are ignored by the IP Telephony device, except for
the user-access attribute: ua.
•
The user-access attribute defines access to the administration web server
for a specific parameter by the User account. Access by the Admin account
is unaffected by this attribute.
•
The ua attribute, if present, must have one of the following values:
-
na—no access
-
ro—read-only
-
rw—read/write
The ua attribute is illustrated by the following example:
<flat-profile>
<SIP_TOS_DiffServ_Value_1_
<Dial_Plan_1_
<Dial_Plan_2_
</flat-profile>
•
If the user-access attribute (ua) is not specified in an element tag, the
factory default user access is applied for the corresponding parameter.
Parameters
•
Any parameters that are not specified by a profile are left unchanged in the
IP Telephony device.
•
Unrecognized parameters are ignored.
ua="na"/>
ua="ro"/>
ua="rw"/>
2
31