Cisco FAN-MOD-3 Technical Information page 6

Catalyst 6500 series chassis and module power and heat values

Advertisement

Table D-4
Table D-4
Power Requirements and Heat Dissipation—Policy Feature Cards (PFCs)
Model Number/
Module Type
WS-F6K-PFC3A
Policy Feature Card 3A
WS-F6K-PFC3B
Policy Feature Card 3B
WS-F6K-PFC3BXL
Policy Feature Card 3BXL
VS-F6K-PFC3C
Policy Feature Card 3C
VS-F6K-PFC3CXL
Policy Feature Card 3CXL
Table D-5
Table D-5
Power Requirements and Heat Dissipation—Distributed Forwarding Cards (DFCs)
Model Number/
Module Type
WS-F6K-DFC
Distributed Forwarding Card
WS-F6K-DFC3A
Distributed Forwarding Card 3A
WS-F6K-DFC3B
Distributed Forwarding Card 3B
WS-F6K-DFC3BXL
Distributed Forwarding
Card 3BXL
WS-F6700-CFC
Centralized Forwarding Card
Catalyst 6500 Series Switches Installation Guide
D-6
lists the power and the heat numbers for the Policy Feature Cards (PFCs).
Module
Module
Current (A)
Power
(Watts)
2.25
94.50
1.47
61.74
2.57
107.94
1.90
79.80
2.50
105.00
lists the power and the heat numbers for the Distributed Forwarding Cards (DFCs).
Module
Module
Current (A)
Power
(Watts)
2.10
88.20
2.57
107.94
1.67
70.14
2.38
99.96
0.75
31.5
Appendix D
AC
DC
AC-Input
Heat Diss.
DC-Input
Power
(BTU/HR)
Power
(Watts)
(Watts)
118.13
403.40
127.02
77.18
263.55
82.98
134.93
460.77
145.08
99.75
340.65
107.26
131.25
448.22
141.13
AC
DC
AC-Input
Heat Diss.
DC-Input
Power
(BTU/HR)
Power
(Watts)
(Watts)
110.25
376.50
118.55
134.93
460.77
145.08
87.68
299.41
94.27
124.95
426.70
134.35
39.38
134.47
42.34
Chassis and Module Power and Heat Values
Heat Diss.
(BTU/HR)
433.76
283.39
495.45
366.29
481.96
Heat Diss.
(BTU/HR)
404.84
495.45
321.95
458.82
144.59