G0623X3 220/440V Operation - Grizzly G0623X Owner's Manual

10" sliding table saw
Hide thumbs Also See for G0623X:
Table of Contents

Advertisement

G0623X3 220/440V
Operation
Serious personal injury could occur if you
connect the machine to the power source
before you have completed the setup pro-
cess. DO NOT connect the machine to the
power source until instructed after setup.
Electrocution or fire could
result if this machine is
not installed to code. You
MUST ensure compliance
by checking with a quali-
fied electrician!
NOTICE
The Model G0623X3 is prewired for 220V
operation. If you plan to use your machine
at 440V, you MUST have a qualified electri-
cian perform the 440V conversion described
on Page 58.
Full Load Amp Draw
G0623X3 220V 3-Phase .........................20 Amp
G0623X3 440V 3-Phase ......................... 10 Amp
Circuit Requirements
You MUST connect your machine to a grounded
circuit that is rated for the amperage given below.
Never replace a circuit breaker on an existing cir-
cuit with one of higher amperage without consult-
ing a qualified electrician to ensure compliance
with wiring codes. If you are unsure about the
wiring codes in your area or you plan to con-
nect your machine to a shared circuit, consult
a qualified electrician.
Minimum Circuit Size (220V) ................. 30 Amps
Minimum Circuit Size (440V) ................. 15 Amps
-16-
Power Cord Requirements
For 220V connection, use a stranded-copper flex-
ible cord that meets the minimum requirements
listed below, does not exceed 50 ft., and has an
insulation type that starts with "S." A qualified
electrician MUST determine the best cord to use
in your environment depending on exposure to
moisture, heat, and oils.
For 440V connection, an electrician MUST
hardwire the machine. The electrician who hard-
wires the machine will determine the appropriate
wire to use inside the conduit.
G0623X3 220V 3-Phase ......10/4 AWG, 300VAC
G0623X3 440V 3-Phase ..... Electrician Hardwire
Power Connection Device
The power connection device depends on the
type of installed or planned service. We recom-
mend using one of the devices shown in Figure
3, depending on the voltage being used.
�������
�������
��
��
�������
������������
Figure 3. Recommended connection types.
G0623X/G0623X3 10" Sliding Table Saw
L15-30
Plug & Outlet
for 220V, 3-Phase
Hardwired Locking
Disconnect Switch
for 440V, 3-Phase

Advertisement

Table of Contents
loading

This manual is also suitable for:

G0623x3

Table of Contents