Honeywell UV100E2009 - Ultraviolet Air Treatment System Owner's Manual

Honeywell UV100E2009 - Ultraviolet Air Treatment System Owner's Manual

Ultraviolet system
Hide thumbs Also See for UV100E2009 - Ultraviolet Air Treatment System:

Advertisement

UV100E Ultraviolet System
OWNER'S GUIDE
69-1573-3

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell UV100E2009 - Ultraviolet Air Treatment System

  • Page 1 UV100E Ultraviolet System OWNER’S GUIDE 69-1573-3...
  • Page 2: How Your Ultraviolet Air Treatment System Or Surface Treatment System Works

    Enviracom™ communication terminals to monitor air flowing through your heating and cooling system. The UV system turns on when air is flowing and leaves the lamp on for 40 minutes after the airflow stops. If airflow resumes during the 40 minutes, the timer resets to 40 minutes.
  • Page 3: Surface Treatment System

    With Enviracom™ communication terminals hooked up, your UV System turns off for the Winter 30 days after the last call for cooling occurs. And your UV System turns on and resumes the on/off cycle with the first call for cooling in the Spring.
  • Page 4 To prevent exposure to ultraviolet light, disconnect power to Ultraviolet System before servicing any part of heating and air conditioning system. Do not mount device in location that allows ultraviolet light to be seen after installation. Do not attempt to bypass duct mount switch.
  • Page 5: Mercury Notice

    UV100E ULTRAVIOLET SYSTEM MERCURY NOTICE This device contains mercury in the sealed ultraviolet bulb(s). Do not place your used bulb(s) in the trash. Dispose of properly. Broken Bulb Cleanup. Do not use a household vacuum. Sweep debris (phosphor/glass) into a plastic bag and dispose of properly.
  • Page 6: How You Can Check Your Ultraviolet System

    Do not attempt to look into the duct at the illuminated bulb(s). If the light is not on when you check your UV System, briefly push the reset button for one second. This brings the lamp on for 40 minutes (Air Treatment System) or for 30 minutes (Surface Treatment System).
  • Page 7: How You Can Maintain Your Uv System

    Fig. 4. UV bulb cleaning reminder schedule. To clean your bulbs: 1. Disconnect the power to your heating and cooling system. 2. Unplug or turn off power to your UV System and allow the bulb to cool for at least 15 minutes. 69-1573—3...
  • Page 8 4. Holding the lamp handle, wipe the lamp glass using a soft cloth dampened with glass cleaner. If you touch the lamp glass with your hands, be sure to clean the area of any oils left from bare hands. See Fig. 6.
  • Page 9 UV100E ULTRAVIOLET SYSTEM 6. Dry bulb with a clean, dry cloth. 7. Insert the bulb into the base with the lamp light indicator at the eleven o’clock position. Continue pushing and gently rotating counterclockwise until the lamp handle inserts fully into the base. See Fig. 8.
  • Page 10: Bulb Replacement

    Surface Treatment System 2. Disconnect the power to your heating and cooling system. 3. Unplug or turn off power to your UV System and allow the bulb to cool for at least 15 minutes. 4. Rotate the lamp handle counterclockwise and gently pull the lamp handle to remove the bulb.
  • Page 11 M22854 Fig. 11. Replace lamp glass in SnapLamp™ handle. 7. Insert the bulb into the base with the lamp light indicator at the eleven o’clock position. Continue pushing and gently rotating counterclockwise until the lamp handle inserts fully into the base. See Fig. 8.
  • Page 12: Five-Year Limited Warranty

    If the product is defective, (i)return it, with a bill of sale or other dated proof of purchase, to the retailer from which you purchased it, or (ii)package it carefully, along with proof of purchase (including date of purchase) and a short...

This manual is also suitable for:

Uv100e3007 - uv surface treatment systemUv100e

Table of Contents