Honeywell F50F Product Data
Honeywell F50F Product Data

Honeywell F50F Product Data

Duct mounted electronic air cleaner
Hide thumbs Also See for F50F:

Advertisement

Duct Mounted Electronic Air Cleaner
APPLICATION
The high efficiency Electronic Air Cleaner is mounted in the
return air duct of a forced air heating, cooling, or ventilating
system. It captures a significant amount of the airborne
particles 0.5 microns and larger from the air circulated
through it.
® U.S. Registered Trademark
Copyright © 1998 Honeywell Inc. • All Rights Reserved
FEATURES
• Available in five sizes to fit most ducts; adapts to
airflow from either side.
• Has one or two cells, depending on cabinet size.
• Capacity varies from 1000 cfm (1700 m3/hr) to
3
2000 cfm (3400 m
/hr), depending on size.
• Solid state power supply is self-regulating and
maintains peak efficiency during a wide range of
cell dirt loading conditions.
• Pressure drop is approximately equal to that of a
regular fiberglass filter.
• Optional W8600F Air Cleaner Monitor indicates air
cleaner performance, reminds homeowner when a
cell and prefilter wash is due, and when to check
the system.
• Electronic cell(s) can be washed in most home
dishwashers.
• Galvanized cabinet protects against rust.
• Neon light next to on-off switch tells if air cleaner is
powered and if high voltage is present.
• Test button checks system operation.
• Troubleshooting guide mounted inside cell access
door.
• Permanent wash reminder schedule included for
mounting in convenient location.
• Prefilter screen(s) protects cell(s) from large dirt
particles.
Application ........................................................................
Features ............................................................................
Specifications ....................................................................
Ordering Information .........................................................
Planning the Installation ...................................................
Installation .........................................................................
Operation .......................................................................... 13
Checkout ........................................................................... 13
Service .............................................................................. 13
Replacement Parts/Exploded View .................................. 18
Electrical Troubleshooting ................................................. 20
F50F
PRODUCT DATA
Contents
1
1
2
2
4
7
68-0137-5

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell F50F

  • Page 1: Table Of Contents

    Ordering Information ............Planning the Installation ........... Installation ................. Operation ................13 Checkout ................13 Service ................13 Replacement Parts/Exploded View ........18 Electrical Troubleshooting ..........20 ® U.S. Registered Trademark 68-0137-5 Copyright © 1998 Honeywell Inc. • All Rights Reserved...
  • Page 2: Specifications

    Honeywell Inc., 1985 Douglas Drive North Minneapolis, Minnesota 55422-4386 In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
  • Page 3 F50F DUCT MOUNTED ELECTRONIC AIR CLEANER AIR CLEANER EFFICIENCY AND PRESSURE DROP AT VARIOUS AIRFLOW RATES. [62.2] 16 x 20 in. [406 x 508 mm] [49.7] 20 x 25 in. 16 x 25 in. [508 x 635 mm] [406 x 635 mm] [37.3]...
  • Page 4: Planning The Installation

    F50F DUCT MOUNTED ELECTRONIC AIR CLEANER 8 (162) DIM. E ELECTRONIC AIR CLEANER (SEE TABLE) DIM. B DIM. A (SEE TABLE) (SEE TABLE) (22) DIM. C (SEE TABLE) (22) (16) (172) DIM. D (SEE TABLE) DIM. A DIM. B DIM. C DIM.
  • Page 5 20 degrees expansion per side, per fitting. between the access door and any obstructions for cell and prefilter maintenance. NOTE: Honeywell does not offer carbon filters. Refer to an activated carbon filter manufacturer for sizing and — Upflow “Highboy” furnace: Side installation; air cleaner is application.
  • Page 6 F50F DUCT MOUNTED ELECTRONIC AIR CLEANER M11973 Fig. 3. Mounting positions with variety of furnace installations. Determine Duct Design Requirements CHANGE DUCT SIZE GRADUALLY TO MINIMIZE TURBULENCE. The air cleaner is adaptable to all new or existing forced air 20 DEGREE EXPANSION PER SIDE PER heating, cooling and ventilating systems used in residential FITTING (4 in.
  • Page 7: Installation

    F50F DUCT MOUNTED ELECTRONIC AIR CLEANER Turning Vanes Clean Blower Compartment If the air cleaner is installed close to an elbow or angle Remove and discard the existing furnace filter. fitting, install turning vanes inside the angle to distribute Thoroughly clean the blower compartment.
  • Page 8 The W8600F Air Cleaner Monitor is an option available for • EAC prefilter and cells are past use with the F50F. The series two requires a solid state power SERVICE level of dirt and need to be supply that is compatible with the W8600F driver board. Any washed immediately.
  • Page 9 F50F DUCT MOUNTED ELECTRONIC AIR CLEANER Mounting BACK OF W8600F The following mounting instructions assume that the W8600F is mounted next to a T8600 Thermostat. If installing the BATTERY monitor at another location, modify the procedure to fit the IN HOLDER installation.
  • Page 10 ELECTRONIC AIR CLEANER TERMINAL STRIP ON POWER BOX GREEN BLUE THREE-WIRE M5640A THERMOSTAT CABLE Fig. 14. Crimping prefilter guide. CONNECT TO W8600F TERMINALS BEFORE CONNECTING TO POWER BOX. M11974 Fig. 12. Wiring W8600F to F50F power box terminal strip (two-cell model). 68-0137—5...
  • Page 11: Complete Wiring

    F50F DUCT MOUNTED ELECTRONIC AIR CLEANER INSTALL HANDLE ON END OF CELL Position Cell Key CLOSEST TO ACCESS DOOR. The electronic cell must always be installed so the ionizer section is on the upstream side. A factory-installed cell key on the bottom of the cabinet allows the cell to be inserted in only one direction.
  • Page 12 F50F DUCT MOUNTED ELECTRONIC AIR CLEANER BLACK COLLECTOR TEST RED IONIZER BUTTON BLACK CONTACT BOARD BLACK BLACK POWER SUPPLY BROWN BLACK BLUE ORANGE GRAY VIOLET GREEN BLACK BLACK BLACK 1 INTERLOCK SWITCH. W4 W2 W1 W3 2 SHORTING BAR. 3 AIRFLOW SWITCH DISABLE JUMPER.
  • Page 13: Operation

    F50F DUCT MOUNTED ELECTRONIC AIR CLEANER 2. Turn off the system blower. The neon light should go WIRING off after a few seconds. The neon light shows that the COMPARTMENT air cleaner is energized and the high voltage power ELECTRONIC...
  • Page 14 F50F DUCT MOUNTED ELECTRONIC AIR CLEANER IMPORTANT NOTE: Sharp corners on the cell(s) can scratch the • Check the dishwasher owner’s manual. Some surface of a bathtub. manufacturers do not recommend washing electronic cell(s) in their dishwashers. 2. Dissolve about 3/4 cup of automatic dishwasher •...
  • Page 15: Modification To Reduce Ozone Odor

    F50F DUCT MOUNTED ELECTRONIC AIR CLEANER 3. Check the cell for short circuits using an ohmmeter. Check the resistance between the frame of the cell and both the ionizer and the collector contacts. In each HIGH VELOCITY case, the resistance should be infinite. See Fig. 23.
  • Page 16 F50F DUCT MOUNTED ELECTRONIC AIR CLEANER However, if desired, the ozone generated by the air cleaner COLLECTOR TERMINAL can be reduced in one of two ways: IONIZER 1. Install an activated carbon filter downstream from the TERMINAL air cleaner. Make sure particles from the air filter COLLECTOR cannot fall into the air cleaner.
  • Page 17 F50F DUCT MOUNTED ELECTRONIC AIR CLEANER REMOVE POWER BOX FROM AIR CLEANER AND REMOVE THE COVER. M6168A Fig. 24. Remove power box from air cleaner and remove cover. J5 SHUNT IN OZONE REDUCTION POSITION E5 E6 J5 IN NORMAL E4 E3...
  • Page 18: Replacement Parts/Exploded View

    F50F DUCT MOUNTED ELECTRONIC AIR CLEANER REPLACEMENT PARTS/EXPLODED VIEW Nominal Return Air Opening 16 x 20 in. 16 x 25 in. 20 x 12-1/2 in. 20 x 20 in. 20 x 25 in. Description (406 x 508 mm) (406 x 635 mm)
  • Page 19 F50F DUCT MOUNTED ELECTRONIC AIR CLEANER M3751 Fig. 26. Components of the Electronic Air Cleaner (2-cell model shown). 68-0137—5...
  • Page 20: Electrical Troubleshooting

    F50F DUCT MOUNTED ELECTRONIC AIR CLEANER Parts and Accessories Not Illustrated Nominal Return Air Opening 16 x 20 in. 16 x 25 in. 20 x 12-1/2 in. 20 x 20 in. 20 x 25 in. Description (406 x 508 mm)
  • Page 21 F50F DUCT MOUNTED ELECTRONIC AIR CLEANER TROUBLE SHOOTING AIR CLEANERS WITH PERFORMANCE INDICATOR. START TO USE THIS CHART: FOLLOW THE STEPS IN ORDER; DO NOT SKIP AROUND. EACH TIME YOU ISOLATE AND FIX A PROBLEM, GO BACK TO START. REPEAT ALL THE STEPS UNTIL THE AIR CLEANER CHECKS OUT OK.
  • Page 22 F50F DUCT MOUNTED ELECTRONIC AIR CLEANER 68-0137—5...
  • Page 23 F50F DUCT MOUNTED ELECTRONIC AIR CLEANER 68-0137—5...
  • Page 24 Home and Building Control Home and Building Control Honeywell Asia Pacific Inc. Honeywell Inc. Honeywell Limited-Honeywell Limitée Room 3213-3225 Honeywell Plaza 155 Gordon Baker Road Sun Hung Kai Centre P.O. Box 524 North York, Ontario No. 30 Harbour Road Minneapolis MN 55408-0524...

Table of Contents