5. If you have a SnapLamp™ handle, follow steps 5 and 6; otherwise, proceed to
step 7. Grasp the SnapLamp™ handle in one hand and the lamp glass in the
other and pull straight apart. See Fig. 10.
Fig. 10. Disconnect lamp glass from SnapLamp™ handle.
6. Insert the new lamp glass into the SnapLamp™ handle by aligning the key and
pushing straight together. See Fig. 11.
Fig. 11. Replace lamp glass in SnapLamp™ handle.
7. Insert the bulb into the base with the lamp light indicator at the eleven o'clock
position. Continue pushing and gently rotating counterclockwise until the lamp
handle inserts fully into the base. See Fig. 8.
8. Rotate the lamp clockwise until it snaps into place with the lamp light indicator
aligned with the raised button on the unit cover. See Fig. 9.
9. Reconnect power to your UV System.
10. For UV Air Treatment Systems, wait ten minutes for the airflow sensor to
calibrate. During this time, the furnace fan must remain off.
NOTE: Failure to wait ten minutes for the airflow sensor to calibrate before powering
the system fan causes the airflow sensor to incorrectly calibrate and the
device to incorrectly function. If this occurs, remove power to the furnace or
turn off the system fan, wait ten minutes, and then resume normal fan
operation.
11. Verify that your ultraviolet bulbs are operating by viewing only through the lamp
light indicator on the lamp handle. Never look directly at your bulbs while
illuminated.
12. Reconnect power to your heating and cooling system.
13. Press and hold the reset button for five seconds to reset the internal timers.
UV100E ULTRAVIOLET SYSTEM
11
M22852
M22854
69-1573—3